ASCO™ 308 Series Manual Reset Solenoid Valve
The ASCO 308-S Series is a manual reset solenoid valve with a high-flow/high-pressure body design, intended to prevent accidental valve actuation.
- Originalware, zehnfacher Ersatz bei Fälschung
- Gerätegarantie, lebenslange Wartung
- Lagerbestand, Versand am selben Tag
The ASCO 308-S Series is a manual reset solenoid valve with a high-flow/high-pressure body design, intended to prevent accidental valve actuation. Its intrinsically safe construction is ideal for critical process control in biofuel and refining applications.
Key specifications: Function: three-way – 3/2 universal; Body material: brass, stainless steel; Operating environment: corrosive, indoor, outdoor, hazardous.
Die in dieser Serie erhältlichen Modelle umfassen JBEF8308G360.24/DC, IS8308G046.24/DC, EV8308G361.24/DC, EVHT8308G360.24/DC, JE8308G040.110/50-60, EFX8308-044.24/DC.25006 und weitere; insgesamt sind 8 gängige Bestellnummern zusammengestellt. Die vollständige Liste finden Sie in der Tabelle der technischen Daten unten unter „Optionale Modelle“.
| Parametername | Technische Daten |
|---|---|
| Hauptspezifikationen | |
| Ventilbetätigung | Handrückstellung |
| Ventilkörpermaterial | Messing, Edelstahl |
| Medium | Korrosive Flüssigkeiten/Gase, Luft, Inertgase, Leichtöle, Dampf, Wasser |
| Rohr-/Anschlussgröße | 1/4 "; 1/2 "; 3/8 "; 3/4 "; 1 " |
| Anschlussart | NPTF |
| Funktionen | 3-Wege – 3/2 universal |
| Durchflusskoeffizient | 0,1 Cv bis 0,5 Cv; 0,5 Cv bis 1,0 Cv; 1,0 Cv bis 2,0 Cv; 2,0 Cv bis 6,0 Cv; 6,0 Cv bis 14,0 Cv |
| Spannung | 24 AC, 110 AC, 120 AC, 480 AC, 6 DC, 12 DC, 24 DC, 48 DC, 120 DC, 240 DC, 125 DC battery charging, 250 DC battery charging | 60 |
| Max. Differenzdruck / max. Betriebsdruck | 150-500 PSIG |
| Betriebsumgebung | Korrosiv, Innenbereich, Außenbereich, explosionsgefährdet |
| Normen/Vorschriften | CSA; Klasse 1; Klasse 3; Klasse 7; Klasse 9 |
| Optionale Modelle | |
| JBEF8308G360.24/DC | |
| IS8308G046.24/DC | |
| EV8308G361.24/DC | |
| EVHT8308G360.24/DC | |
| JE8308G040.110/50-60 | |
| EFX8308-044.24/DC.25006 | |
| 8308B040.120/DC | |
| 8308A011.24/DC | |
- Available with electrical trip (energize-to-trip), no-voltage release (trip on de-energization), or lever handle construction. Once tripped, the valve can only be reset manually
- Open-position locking or closed-position locking operation can be achieved.
- Certain constructions withstand corrosive fluids (including steam)
- Operates in harsh environments. Up to SIL 3 capable
- Handles aggressive atmosphere per salt resistance testing (ASTM B117)
- SIL 3 capable, certified by Exida
- Optional position indicator switch provides diagnostic feedback (GO™ Switch, suffix SP)
Dampfregelung in Kesseln und Wärmetauschern
In Dampfleitungen werden hochtemperaturbeständige Ausführungen eingesetzt, die entsprechend der Prozesstemperatur automatisch öffnen und schließen und so Wärmeverluste reduzieren.
Automatisierte Steuerung von Prozessventilen
Diese Magnetventilbaureihe wird in den pneumatischen Steuerleitungen von Prozessventilen in Raffinerieanlagen installiert, empfängt digitale Schaltausgänge der DCS und ermöglicht schnelles Öffnen und Schließen sowie Verriegelungsfunktionen der Ventile.
Noch keine Dokumente hochgeladen.
Benötigen Sie Auswahlberatung oder ein Mengenangebot?
Senden Sie uns die Betriebsparameter (Signaltyp, Medium, Messbereich, Druck, Temperatur, Anschlussart) – unsere Ingenieure erstellen Ihnen innerhalb eines Werktages einen Auswahlvorschlag und ein Angebot.
- Telefonische Beratung +86-21-66020232
- Angebotsanfrage per E-Mail web@qishan-sh.com