ASCO™ 215 High-Flow Gas Shut-Off Solenoid Valve
The ASCO 215 Series is a lightweight gas safety shut-off valve with an aluminium body, suitable for high-flow applications.
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
The ASCO 215 Series is a lightweight gas safety shut-off valve with an aluminium body, suitable for high-flow applications. The pilot-operated design operates from zero pressure differential, and the resilient soft seat ensures tight shut-off. Optional flanges support dual solenoid valve and solenoid motorised valve configurations, enabling modularity and ensuring ease of installation. The 215 Series is ideal for vacuum conditions, oxygen conditions, heating equipment applications and long-life applications.
Key specifications: Function: two-way — 2/2 normally closed; two-way — 2/2 normally open; body material: aluminium; operating environment: hazardous; indoor; outdoor.
Models currently available in this series include 8215H080DC24/DCD, 8215H080AC120/60D, 8215H070DC24/DCD, 8215H070DC12/DCD, 8215H070AC120/60D, 8215H060DC12/DCD, etc., with 14 common order codes compiled in total; see the "Optional Models" section of the technical specifications table below for the complete list.
| Parameter Name | Technical Specifications |
|---|---|
| Main specifications | |
| Valve body actuation type | Solenoid |
| Valve body material | Aluminium |
| Medium | Air; inert gas; natural gas; oxygen; vacuum |
| Pipe/port size | 1/2"; 3/8"; 3/4"; 1"; 1 1/4"; 1 1/2"; 2"; 2 1/2"; 3" |
| Interface type | NPT |
| Functions | Two-way — 2/2 normally closed; two-way — 2/2 normally open |
| Voltage | 110 AC; 115 AC; 12 DC; 120 AC; 120 DC; 208 AC; 220 AC; 230 AC; 24 AC; 24 DC; 240 AC; 240 DC; 440 AC; 48 DC; 480 AC; 6 DC - 50/60 |
| Maximum differential pressure/maximum working pressure | 125 psi; 8.6 bar; vacuum (see product catalogue) |
| Operating environment | Hazardous; indoor; outdoor |
| Standards/regulations | Class I Division 1; Class I Division 2; Class II Division 1; Class II Division 2; CSA; FM; Type 1; Type 2; Type 3; Type 3R; Type 3S; Type 4; Type 4X; Type 6; Type 6P; Type 7; Type 9; UL |
| Flow | From 3.4 Cv to 130 Cv (2.9 Kv to 110 Kv) |
| Optional Models | |
| 8215H080DC24/DCD | Two-way - 2/2 normally closed |
| 8215H080AC120/60D | Two-way - 2/2 normally closed |
| 8215H070DC24/DCD | Two-way - 2/2 normally closed |
| 8215H070DC12/DCD | Two-way - 2/2 normally closed |
| 8215H070AC120/60D | Two-way - 2/2 normally closed |
| 8215H060DC12/DCD | Two-way - 2/2 normally closed |
| 8215H060AC120/60D | Two-way - 2/2 normally closed |
| 8215H050DC24/DCD | Two-way - 2/2 normally closed |
| 8215H050DC12/DCD | Two-way - 2/2 normally closed |
| 8215H050AC120/60D | Two-way - 2/2 normally closed |
| 8215G090AC120/60D | Two-way - 2/2 normally closed |
| 8215G040AC120/60D | Two-way - 2/2 normally closed |
| 8215G030AC24/60,22/50D | Two-way - 2/2 normally closed |
| 8215G030AC208/60D | NPT 3/4 | Two-way - 2/2 normally closed | Cv 5.10 | NBR seal |
- Watertight and corrosion-resistant Type 4X solenoid enclosure for all constructions
- Solenoids now certified for explosion-proof/hazardous locations
- Fully certified by UL, CSA and FM as a safety shut-off valve
- Closed-position proof switch and visual indication meet regulatory/legislative requirements for electrical interlock of valve closed position
- Optional mounting flange models for a variety of mounting and valve connections
- Optional NPT threaded termination kit
- New high-flow option for 1.25 in, 1.5 in and 2 in pipe size configurations
- 1/8-inch NPT wall port with plug for routine testing
Process valve automation control
Install this solenoid valve series on the process valve air lines in refinery units to receive DCS digital outputs and achieve rapid valve opening/closing and interlock actions.
Boiler and heat exchanger steam control
Configure high-temperature-resistant models on steam lines to open and close automatically according to process temperature, reducing heat loss.
No documents uploaded yet.
Need selection advice or bulk quotation?
Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.
- Phone consultation +86-21-66020232
- Email inquiry web@qishan-sh.com



