MinIPAQ R230 Rail Temperature Transmitter
Universal non-isolated two-wire rail-mounted transmitter, supporting RTD, thermocouple, resistance and mV inputs, configurable via NFC / Bluetooth or PC.
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
The MinIPAQ R230 is a universal, non-isolated, two-wire rail-mounted transmitter for temperature measurement and other measurement applications.
Its robust design and high-quality components ensure good performance and accuracy even under harsh conditions. The transmitter accepts a wide range of resistance thermometer (RTD), thermocouple (TC) and linear resistance and mV signal inputs.
The transmitter is easily configured via the INOR Connect mobile app — either wirelessly via NFC or via a connected Bluetooth® modem; configuration can also be completed using ConSoft software on a PC.
| Parameter Name | Technical Specifications |
|---|---|
| Basic Parameters | |
| Product Type | Universal digital rail-mounted two-wire signal transmitter |
| Installation Method | Mounted on 35 mm DIN rail in accordance with EN/IEC 60715 |
| Input | |
| Input Signal | Resistance thermometer (RTD), thermocouple (TC), mV and Ω |
| Resistance input (2/3/4-wire) | Pt10…Pt1000, Ni100, Ni120, Ni1000 |
| Thermocouple Input | Types B, C, D, E, J, K, N, R, S, T |
| mV input | -10…+1000 mV |
| Resistance input (2/3/4-wire) | 0…4000 Ω (0…2000 Ω in 2-wire connection) |
| Output and Communication | |
| Output Signal | 4-20 mA (RTD, TC temperature linear), two-wire loop-powered |
| Output signal and sensor fault | Compliant with NAMUR NE43 |
| Configuration Mode | ConSoft Windows software or INOR Connect mobile app |
| Wireless configuration | NFC and Bluetooth® |
| Power Supply and Isolation | |
| Electrical Isolation | No isolation, non-isolated |
| Supply voltage (with polarity protection) | 8…36 VDC |
| Accuracy and Environment | |
| Typical accuracy (RTD) | Max. ±0.15 K or ±0.15% of span |
| Typical accuracy (type J, K thermocouples) | Max. ±0.5 K or ±0.25% of span, ±1 K (cold junction compensation) |
| Long-term drift | Max. ±0.05% of span/year |
| Vibration Resistance | IEC 60068-2-6, 5 g |
| Certification and Compliance | |
| Electromagnetic Compatibility (EMC) | Compliant with EN 61326-1 and EN 61326-2-3 |
| RoHS | Compliant with RoHS directive |
- Resistance thermometer (RTD) and resistance input, supporting 2-wire, 3-wire and 4-wire connection
- Thermocouple (TC) and mV signal input
- Mounts on 35 mm DIN rail
- Configurable via PC, NFC or Bluetooth®, no external power supply required
- Sensor error correction and system error (sensor + transmitter) correction for higher overall accuracy
- Operating timer, records cumulative operating hours
- Rugged design, tested to 5 g vibration
- High security: parameter changes are password-protected
- Remote configuration and monitoring via connected Bluetooth® modem
General temperature measurement in control cabinets
Rail-mounted centralised installation, one unit covers multiple sensor types, ideal for packaged projects with complex measurement point types.
Water treatment and environmental engineering
Temperature acquisition for tanks, pipes and fans/pumps, with 4-20 mA output connected to the central control system.
Equipment retrofit and expansion
Universal input facilitates retrofit, replacing legacy transmitters without changing sensor type.
Documents not uploaded. Please fill in the information row by row in the 'Product Details Field' panel under 'File Name | Download Address | File Size'.
Need selection advice or bulk quotation?
Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.
- Phone consultation +86-21-66020232