M-LB-Ex-2615 3-Channel Surge Protection Isolator

Product Model M-LB-Ex-2615

Product Brand

Product Category Industrial safety and signal conditioning modules / surge protectors / P+F surge protectors, industrial safety and signal conditioning modules, industrial safety and signal conditioning modules / surge protectors

Application Industry Power Energy, Petroleum Chemical Industry, Process Automation

Surge protection for 3 signal lines, rated voltage 1 V DC, surge protection isolator for ungrounded signal lines, maximum surge current (8/20 µs) 20 kA.

Inquire Now
  • Original Factory Genuine, Tenfold Compensation for Counterfeits
  • Full Machine Warranty, Lifetime Maintenance
  • In Stock, Shipped on the Same Day

Pepperl+Fuchs M-LB-Ex-2615 3-channel surge protection isolator, surge protection for 3 signal lines, rated voltage 1 V DC, surge protection isolator for ungrounded signal lines, maximum surge current (8/20 µs) 20 kA, screw terminal connection.

For lightning and switching overvoltage protection of signal lines, power lines and fieldbus lines between hazardous areas and safe areas, DIN rail or field enclosure mounting, directly connected in series in instrument loops, DCS/PLC I/O and bus trunk/spur lines.

M-LB-Ex-2615 3-Channel Surge Protection Isolator Technical Data
Parameter Name Technical Specifications
General specifications
Number of protected signal lines 3
Topology Ungrounded
Functional safety parameters
Safety Integrity Level (SIL) SIL 3
Electrical Data
Connection Protected area: terminals 4, 5, 6, unprotected area: terminals 1, 2, 3
Rated current 400 mA, for restrictions see derating table
Leakage current < 10 µA at 1 V and 25 °C (77 °F), line-to-line
Rated Voltage 1 V DC
Maximum continuous operating voltage 6 V DC
Series resistance ≤ 3 Ω per line
Impulse withstand rating 1 kV/0.5 kA (category C1), 10 kV/5 kA (category C2), 1 kA (category D1)
Impulse discharge current (10/350 µs) 1 kA per line (2 times)
Nominal discharge current (8/20 µs) 5 kA per line (10 times)
Total discharge current (8/20 µs) 20 kA (1x), overstress failure mode 3 according to IEC 61643-21
Voltage protection level max. 12 V line-to-line (at rated discharge current In), max. 2000 V line-to-ground (at rated discharge current In)
Impulse reset time < 500 ms
Insertion loss ≤ 3 dB at 0 … 170 kHz in 100 Ω system
Conformity
Electromagnetic compatibility EN 61326-3-1:2017
Degree of protection IEC 60529:2013
Functional safety IEC/EN 61508:2010
Low-voltage surge protective device IEC 61643-21:2000+A1:2008+A2:2012
Ambient Conditions
Ambient Temperature −40 … 80 °C (−40 … 176 °F), note that the temperature range is subject to derating, see derating section
Storage Temperature −40 … 85 °C (−40 … 185 °F)
Relative Humidity Max. 95 %, non-condensing
Corrosion resistance According to ISA-71.04, severity level G3
Mechanical parameters
Degree of protection IP20 with insulating separator installed
Connection screw terminals, max. core cross-section 1 x 2.5 mm2
Material Polyamide (PA)
Weight approx. 30 g
Dimensions 6.2 x 93 x 71, 8 mm (0.24 x 3.7 x 2.8 inch) (width × height × depth)
Installation Method Mounts on 35 mm DIN mounting rail in accordance with EN 60715:2001
Hazardous area application data
EU Type Examination Certificate KIWA 19 ATEX 0003 X
Marking II 2(1)G Ex ia [ia Ga] IIC T6 … T4 Gb, [exsign] II (1)D [Ex ia Da] IIIC, [exsign] I (M1) [Ex ia Ma] I
Temperature class T6, T5 or T4, restrictions see derating table
Voltage 30 V
Current 400 mA, for restrictions see derating table
Power 1.4 W, see derating table for restrictions
Internal capacitance Negligible
Internal inductance 30 µH
Directive 2014/34/EU EN IEC 60079-0:2018+AC:2020, EN 60079-11:2012, IEC 60079-11:2023
International approvals
IECEx certificate IECEx KIWA 19.0003X
IECEx marking Ex ia [ia Ga] IIC T6 … T4 Gb, [Ex ia Da] IIIC, [Ex ia Ma] I
General information
Supplementary information Observe the certificates, declarations of conformity, instruction manuals and manuals within the applicable scope. For related information, see www.pepperl-fuchs.com.
  • Surge protection for 3 signal lines
  • Rated voltage 1 V DC
  • Surge protection isolator for ungrounded signal lines
  • Maximum surge current (8/20 µs) 20 kA
  • Screw terminal wiring
  • DIN rail mountable
  • Complies with IEC/EN 61508, up to SIL 3

Petrochemical Plant

Lightning and overvoltage protection for instrument signal circuits

Power Energy System

Surge protection for power and signal lines

Process Automation

Surge protection for fieldbus trunk and spur lines

Documents not uploaded. Please fill in the information row by row in the 'Product Details Field' panel under 'File Name | Download Address | File Size'.

Need selection advice or bulk quotation?

Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Inquire about the product

M-LB-Ex-2615 · M-LB-Ex-2615 3-Channel Surge Protection Isolator

Please enter the requirement description (at least 10 characters)

Online customer service
Online customer service Scan or click to contact directly
Contacts
Miss Chen(Safety barriers, isolators, surge protectors)
陈小姐 个人微信二维码

Scan WeChat QR code to add personal WeChat

QQ:2501529964

Phone:17717626508

Email:chenjing@qishan-sh.com

Miss Lu(Field Instruments, Valve Accessories, Terminal Blocks)
卢小姐 个人微信二维码

Scan WeChat QR code to add personal WeChat

QQ:1695457483

Phone:13636420802

Email:lhm@qishan-sh.com

Mr. Ye(Technical Support, After-Sales Service)

QQ:97010638

Phone:15800474322

Email:web@qishan-sh.com

Online Message

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Please enter the requirement description (at least 10 characters)