F*-LBF-D1.32 Surge Protector
Surge protector with stainless steel housing, flameproof enclosure (Ex d) protection, surge protection for fieldbus "+" and "−" conductors, optional 20 mm or 1/2" NPT thread.
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
Pepperl+Fuchs F*-LBF-D1.32 Surge Protector, surge protector with stainless steel housing, flameproof enclosure (Ex d) protection, surge protection for fieldbus "+" and "−" conductors, optional 20 mm or 1/2″ NPT thread, for FOUNDATION Fieldbus H1 and PROFIBUS PA.
For lightning and switching overvoltage protection of signal lines, power lines and fieldbus lines between hazardous areas and safe areas, DIN rail or field enclosure mounting, directly connected in series in instrument loops, DCS/PLC I/O and bus trunk/spur lines.
| Parameter Name | Technical Specifications |
|---|---|
| General specifications | |
| Design/Installation | Outdoor installation |
| Hazardous area installation | Zone 1 |
| Electrical Data | |
| Rated Voltage | 32 V |
| Per line | 10 kA |
| Total | 10 kA |
| Maximum surge current (8/20 µs) | 10 kA |
| Line/line | 58 V |
| Line/earth | 1700 V |
| Line/line | 50 V |
| Line/earth | 1.2 kV |
| Line/line | Max. 1 ns |
| Line/earth | Max. 100 ns |
| Line/line | 25 pF |
| Line/earth | 15 pF |
| Directive conformity | |
| Directive 2014/30/EU | EN 61326-1:2013 |
| Standards compliance | |
| Electromagnetic compatibility | NE 21:2006 |
| Degree of protection | IEC/EN 60529 |
| Fieldbus standard | IEC 61158-2 |
| Surge protection | IEC 61643-21 |
| Ambient Conditions | |
| Ambient Temperature | −50 … 80 °C (−58 … 176 °F) |
| Storage Temperature | −50 … 85 °C (−58 … 185 °F) |
| Mechanical parameters | |
| Core cross-section | 1.3 mm2 |
| Housing material | Stainless steel 1.4401/316 |
| Degree of protection | IP00/IP67 when correctly installed |
| Weight | 160 g |
| Installation Method | Screw mounting |
| Hazardous area application data | |
| EU Type Examination Certificate | KEMA 04 ATEX 2318 X |
| Marking | II 2G Ex db IIC T6 … T5 Gb |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020, EN 60079-1:2014 |
| International approvals | |
| IECEx certificate | IECEx KEM 09.0067X |
| IECEx marking | Ex db IIC T6 … T5 Gb |
| General information | |
| Supplementary information | The EC type-examination certificate, declaration of conformity, certificate of conformity and instruction manual must be observed within the applicable scope. For information, see www.pepperl-fuchs.com. |
- Surge protector with stainless steel housing
- Flameproof enclosure (Ex d) protection
- Surge protection for fieldbus "+" and "−" conductors
- Optional 20 mm or 1/2" NPT thread
- For FOUNDATION Fieldbus H1 and PROFIBUS PA
Petrochemical Plant
Lightning and overvoltage protection for instrument signal circuits
Power Energy System
Surge protection for power and signal lines
Process Automation
Surge protection for fieldbus trunk and spur lines
Documents not uploaded. Please fill in the information row by row in the 'Product Details Field' panel under 'File Name | Download Address | File Size'.
Need selection advice or bulk quotation?
Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.
- Phone consultation +86-21-66020232
- Email inquiry web@qishan-sh.com