M-LB-2.255.T3.D 2-channel surge protection isolator

Product Model M-LB-2.255.T3.D

Product Brand

Product Category Industrial safety and signal conditioning modules / surge protectors / P+F surge protectors, industrial safety and signal conditioning modules, industrial safety and signal conditioning modules / surge protectors

Application Industry Power Energy, Petroleum Chemical Industry, Process Automation

Surge protection for 2 power supply lines, type 3 (acc. to EN 61643-11), rated voltage 230 V AC, pre-wired unit.

Inquire Now
  • Original Factory Genuine, Tenfold Compensation for Counterfeits
  • Full Machine Warranty, Lifetime Maintenance
  • In Stock, Shipped on the Same Day

Pepperl+Fuchs M-LB-2.255.T3.D 2-channel surge protection isolator, surge protection for 2 power supply lines, type 3 (acc. to EN 61643-11), rated voltage 230 V AC, pre-wired unit, operating status and fault indication per protected line.

For lightning and switching overvoltage protection of signal lines, power lines and fieldbus lines between hazardous areas and safe areas, DIN rail or field enclosure mounting, directly connected in series in instrument loops, DCS/PLC I/O and bus trunk/spur lines.

M-LB-2.255.T3.D 2-channel surge protection isolator technical data
Parameter Name Technical Specifications
General specifications
Device type Type 3 according to EN 61643-11, Class III according to IEC 61643-11
Number of protected power supply lines 2
Suitable components Protection module M-LB-2.255.T3.M
Electrical Data
Rated Voltage 230 V AC, 50 … 60 Hz
Maximum continuous operating voltage 255 V AC, 50 … 60 Hz, 255 V DC
Temporary overvoltage 335 V/5 s (TOV withstand) (L-N), 400 V/5 s (TOV withstand) (L/N-PE), 1200 V+Ucs/200 ms (TOV safe failure) (L+N-PE) 5 s (TOV withstand)
Rated load current 25 A
Nominal discharge current (8/20 µs) 3 kA
Maximum surge current (8/20 µs) 5 kA
Voltage protection level Max. 1.25 kV (L-N), max. 1.5 kV (L/N-PE)
Response time max. 25 ns (L-N), max. 100 ns (L/N-PE)
Short-circuit withstand 6 kA eff at max. supply-side overcurrent protection
Overcurrent protection max. 25 A gL/gG (B 25 A), supply side
Fault indication output
Connection Terminals 11, 12, 14
Output Passive changeover contact
Switching capacity AC: 250 V, 0.5 A, DC: 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A; 24 V/0.5 A
Indication/setting
Display elements Status display / operating status (green) / fault indication (red)
Directive conformity
Directive 2014/35/EU EN 61643-11:2012
Conformity
Degree of protection IEC 60529:2013
Shock resistance EN 60068-2:2010
Vibration Resistance EN 60068-2:2010
Operating conditions
Mounting position indoor
Ambient Conditions
Ambient Temperature −40 … 80 °C (−40 … 176 °F)
Relative Humidity 5 … 95 %
Mechanical parameters
Degree of protection IP20
Core cross-section - min. 0.5 mm2 solid/flexible, - max. 4 mm2 stranded/2.5 mm2 flexible
Housing thermoplastic, colour grey, UL 94 V-0
Weight approx. 120 g
Dimensions 18 x 90 x 72 mm (0.7 x 3.6 x 2.8 inch) (W × H × D), 1 TE (in accordance with DIN 43880)
Installation Method Mounts on 35 mm DIN mounting rail in accordance with EN 60715:2001
Hazardous area application data
Certificate TÜV 22 ATEX 8932 X
Marking II 3G Ex ec IIC T4 Gc
Directive 2014/34/EU EN IEC 60079-0:2018, EN IEC 60079-7:2015+A1:2018
International approvals
UL approval E346845
IECEx certificate IECEx TUR 22.0082X
IECEx marking Ex ec IIC T4 Gc
General information
Supplementary information Observe the certificates, declarations of conformity, instruction manuals and manuals within the applicable scope. For related information, see www.pepperl-fuchs.com.
  • Surge protection for 2 supply lines
  • Type 3 (acc. to EN 61643-11)
  • Rated voltage 230 V AC
  • Pre-wired unit
  • Operating status and fault indication per protected line
  • Fault indication output
  • DIN rail mountable

Petrochemical Plant

Lightning and overvoltage protection for instrument signal circuits

Power Energy System

Surge protection for power and signal lines

Process Automation

Surge protection for fieldbus trunk and spur lines

Documents not uploaded. Please fill in the information row by row in the 'Product Details Field' panel under 'File Name | Download Address | File Size'.

Need selection advice or bulk quotation?

Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Inquire about the product

M-LB-2.255.T3.D · M-LB-2.255.T3.D 型 2 通道浪涌保护隔离器

Please enter the requirement description (at least 10 characters)

Online customer service
Online customer service Scan or click to contact directly
Contacts
Miss Chen(Safety barriers, isolators, surge protectors)
陈小姐 个人微信二维码

Scan WeChat QR code to add personal WeChat

QQ:2501529964

Phone:17717626508

Email:chenjing@qishan-sh.com

Miss Lu(Field Instruments, Valve Accessories, Terminal Blocks)
卢小姐 个人微信二维码

Scan WeChat QR code to add personal WeChat

QQ:1695457483

Phone:13636420802

Email:lhm@qishan-sh.com

Mr. Ye(Technical Support, After-Sales Service)

QQ:97010638

Phone:15800474322

Email:web@qishan-sh.com

Online Message

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Please enter the requirement description (at least 10 characters)