M-LB-4272 2-channel surge protection isolator

Product Model M-LB-4272

Product Brand

Product Category Industrial safety and signal conditioning modules / surge protectors / P+F surge protectors, industrial safety and signal conditioning modules, industrial safety and signal conditioning modules / surge protectors

Application Industry Power Energy, Petroleum Chemical Industry, Process Automation

Surge protection for 2 signal lines, rated voltage 180 V, surge protection isolator for ungrounded signal lines, max. surge current (8/20 µs) 12.5 kA.

Inquire Now
  • Original Factory Genuine, Tenfold Compensation for Counterfeits
  • Full Machine Warranty, Lifetime Maintenance
  • In Stock, Shipped on the Same Day

Pepperl+Fuchs M-LB-4272 2-channel surge protection isolator, surge protection for 2 signal lines, rated voltage 180 V, surge protection isolator for ungrounded signal lines, max. surge current (8/20 µs) 12.5 kA, uninterrupted operation (automatic reset).

For lightning and switching overvoltage protection of signal lines, power lines and fieldbus lines between hazardous areas and safe areas, DIN rail or field enclosure mounting, directly connected in series in instrument loops, DCS/PLC I/O and bus trunk/spur lines.

M-LB-4272 2-channel surge protection isolator technical data
Parameter Name Technical Specifications
General specifications
Device type Type 1 according to EN 61643-11
Number of protected signal lines 2
Topology Ungrounded
Functional safety parameters
Safety Integrity Level (SIL) SIL 3
Electrical Data
Connection Protected area: terminals 1', 2', unprotected area: terminals 1, 2
Leakage current < 50 nA at Uc, line-to-line, < 50 nA at Uc, line-to-ground
Rated Voltage 180 V
Maximum continuous operating voltage 127 V AC and 180 V DC
Rated load current 1.2 A at 80 °C (176 °F)
Series resistance 0 Ω per line
Impulse discharge current (10/350 µs) 1.5 kA per line
Nominal discharge current (8/20 µs) 5 kA per line
Maximum surge current (8/20 µs) 12.5 kA
Total discharge current (8/20 µs) 10 kA
Voltage protection level Max. 1100 V line-to-line (at rated discharge current In), max. 800 V line-to-earth (at rated discharge current In)
Impulse reset time < 30 ms
Cut-off frequency 150 MHz, line-to-line
Indication/setting
Display elements Status display / operating status (green) / fault indication (red)
Conformity
Degree of protection IEC 60529:2013
Functional safety IEC/EN 61508:2010
Low-voltage surge protective device EN 61643-21:2001+A1:2009+A2:2013, IEC 61643-21:2001+A1:2008+A2:2012
Ambient Conditions
Ambient Temperature −40 … 80 °C (−40 … 176 °F)
Storage Temperature −40 … 80 °C (−40 … 176 °F)
Relative Humidity Max. 95 %, non-condensing
Corrosion resistance According to ISA-71.04, severity level G3
Mechanical parameters
Degree of protection IP20
Connection Spring terminals (push-in connection)
Core cross-section 0.2 … 2.5 mm2 one wire, 0.2 … 2.5 mm2 fine-strand
Housing Polyamide PA 6.6
Weight Approx. 35 g
Dimensions 6 x 90 x 69 mm (0.24 x 3.5 x 2.7 inch) (W x H x D)
Installation Method Mounts on 35 mm DIN mounting rail in accordance with EN 60715:2001
Hazardous area application data
Certificate TÜV 22 ATEX 8881 X
Marking II 3G Ex ec IIC T4 Gc
Temperature class T4 at ambient temperature ≤80 °C
Directive 2014/34/EU EN 60079-0:2018, EN IEC 60079-7:2015+A1:2018
International approvals
UL approval E501704
IECEx certificate IECEx TUR 22.0051X
IECEx marking Ex ec IIC T4 Gc
General information
Supplementary information Observe the certificates, declarations of conformity, instruction manuals and manuals within the applicable scope. For related information, see www.pepperl-fuchs.com.
  • Surge protection for 2 signal lines
  • Rated voltage 180 V
  • Surge protection isolator for ungrounded signal lines
  • Max. surge current (8/20 µs) 12.5 kA
  • Uninterrupted operation (automatic reset)
  • Status indicator
  • Modular design, pluggable
  • Complies with IEC/EN 61508, up to SIL 3

Petrochemical Plant

Lightning and overvoltage protection for instrument signal circuits

Power Energy System

Surge protection for power and signal lines

Process Automation

Surge protection for fieldbus trunk and spur lines

Need selection advice or bulk quotation?

Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Inquire about the product

M-LB-4272 · M-LB-4272 型 2 通道浪涌保护隔离器

Please enter the requirement description (at least 10 characters)

Online customer service
Online customer service Scan or click to contact directly
Contacts
Miss Chen(Safety barriers, isolators, surge protectors)
陈小姐 个人微信二维码

Scan WeChat QR code to add personal WeChat

QQ:2501529964

Phone:17717626508

Email:chenjing@qishan-sh.com

Miss Lu(Field Instruments, Valve Accessories, Terminal Blocks)
卢小姐 个人微信二维码

Scan WeChat QR code to add personal WeChat

QQ:1695457483

Phone:13636420802

Email:lhm@qishan-sh.com

Mr. Ye(Technical Support, After-Sales Service)

QQ:97010638

Phone:15800474322

Email:web@qishan-sh.com

Online Message

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Please enter the requirement description (at least 10 characters)