SC3012 switch input isolator (one in, two out, relay output)
Single-channel one in, two out switch input isolator: one dry contact signal is isolated and output as two relays; the second channel can be set via DIP switch to signal output or fault alarm output.
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
Same as SC3011, single-channel one in, two out configuration; the second output function can be set via DIP switch to relay output or fault alarm output. Requires independent power supply; three-way isolation between input, output and power supply.
Note:Three-way isolation between input, output and power supply. 24V DC independent power supply; input side connects to dry contact switch or NAMUR proximity switch; output side includes output 1 and output 2 relay contacts; the second output function is set via DIP switch to signal output or fault alarm output. Module indicators: green power indicator, red fault signal, yellow channel status. All terminals are hot-swappable. Refer to the module side silkscreen for specific terminal numbers.
Ordering information:
- Requires independent power supply (18V DC~32V DC).
- The second output function (signal output/fault alarm output) must be confirmed via DIP switch at ordering or before commissioning.
| Parameter Name | Technical Specifications |
|---|---|
| Power supply and power consumption | |
| Power Supply | 18V DC ~32V DC power reverse protection |
| Power consumption | 1W |
| Input characteristics | |
| Input Signal | Dry contact or NAMUR proximity switch |
| Switching characteristics | Input current>2.1mA, output relay closed, channel indicator yellow steady on; input current<1.2mA, output relay open, channel indicator yellow off |
| Open-circuit voltage | Approx. 8.5V |
| Short-circuit current | Approx. 8.5mA |
| Line fault | Input current≤50μA, input wire break detected, output relay open; input current≥6.5mA, input short circuit detected, output relay open; channel indicator red flashing |
| Output and load | |
| Output Signal | Relay contacts |
| Permissible load | 250VAC/2A or 30VDC/2A |
| Drive current | ≤40mA |
| External voltage | <40V DC |
| Switching frequency | <20ms |
| Isolation and electromagnetic compatibility | |
| Electromagnetic compatibility | <10Hz |
| Dielectric strength | ≥1500V AC (between input/output/power supply) |
| Insulation resistance | ≥100MΩ (between input/output/power supply) |
| Environmental and Mechanical | |
| IP Protection | IP20 |
| Operating Temperature | -20℃~+60℃ |
| Storage Temperature | -40℃~+80℃ |
| Dimensions | 12.8mm×110mm×117mm (W×H×D) |
| DIP switch settings | |
| DIP switch | S1–S4: non-inverting/inverting logic, line fault monitoring switch, second output function (relay output or fault alarm output) |
- One in, two out dual relay output; the second output function can be set via DIP switch to signal output or fault alarm output
- The same dry contact/proximity switch signal can be sent simultaneously to both DCS and PLC systems for sharing
- DIP switch settings for non-inverting/inverting logic (default non-inverting), line fault monitoring (default enabled)
- Online monitoring of input open circuit/short circuit; on fault, output opens and indicator flashes
- Three-way isolation between input, output and power supply; no grounding required
- DIN rail mounting, hot-swappable terminals
One signal shared by two systems
The same dry contact/proximity switch signal sent simultaneously to DCS and PLC; or one signal output and one fault alarm output