SC3037 Potentiometer Transmitter (dual channel)

Product Model SC3037

Product Brand

Product Category Industrial Safety and Signal Conditioning Module / Signal Isolator

Application Industry Petrochemical, process automation

Dual-channel potentiometer transmitter: two 3-wire potentiometer signals are each isolated and converted to standard current/voltage signals, centrally installed.

Inquire Now
  • Original Factory Genuine, Tenfold Compensation for Counterfeits
  • Full Machine Warranty, Lifetime Maintenance
  • In Stock, Shipped on the Same Day

Dual-channel configuration; two 3-wire potentiometer signals are each isolated and converted to current/voltage signals. Requires independent power supply; three-port isolation between input, output and power supply; with online fault self-diagnostics.

Note:Three-port isolation between input, output and power supply. 24V DC independent power supply; each of the two inputs connected as a 3-wire potentiometer; output signal types for the two channels determined by the ordering code. Module indicators: green power indicator, red fault signal. Terminals are hot-swappable. Refer to the module side silkscreen for specific terminal numbers.

Ordering information:

  • The output signal types of both channels must be confirmed via the ordering code.
  • Power supply default 24VDC.
SC3037 Potentiometer Transmitter (Dual Channel) Technical Specifications
Parameter Name Technical Specifications
Power supply and power consumption
Power Supply 18V DC~60V DC power reverse protection
Full-load power consumption 0.8W (24V, single channel full load output); 1.2W (24V, dual channel full load output)
Input characteristics
Input Signal 3-wire potentiometer 0kΩ~10kΩ
Output and load
Output Signal Current: active/passive 0/4~20mA, 0~10mA; Voltage: 0/1~5V, 0~10V
Load requirements 0/4~20mA: RL≤550Ω; 0~10mA: RL≤1.1kΩ; 0/1~5V: RL≥1MΩ; 0~10V: RL≥2MΩ
Permissible load Passive: RL<[(U-3)/0.02]Ω; U is the loop voltage
Accuracy and response
Conversion accuracy 0.1%F.S
Temperature drift 30ppm/℃
Response time ≤500ms
Isolation and electromagnetic compatibility
Electromagnetic compatibility IEC 61326-3-1
Dielectric strength ≥1500V AC (between input/output/power supply)
Insulation resistance ≥100MΩ (between input/output/power supply)
Environmental and Mechanical
IP Protection IP20
Operating Temperature -20℃~+60℃
Storage Temperature -40℃~+80℃
Dimensions 17.8mm×110mm×117mm (W×H×D)
Product Selection Code
Output signal (channel 1) (code 1) Defaults to standard 4-20mA output
Output signal (channel 1) (code 2) 1~5V
Output signal (channel 1) (code 3) 0~10mA
Output signal (channel 1) (code 4) 0~5V
Output signal (channel 1) (code 5) 0~10V
Output signal (channel 1) (code 6) 0~20mA
Output signal (channel 1) (code 7) Other customised signals
Output signal (channel 2) (code 1) Defaults to standard 4-20mA output
Output signal (channel 2) (code 2) 1~5V
Output signal (channel 2) (code 3) 0~10mA
Output signal (channel 2) (code 4) 0~5V
Output signal (channel 2) (code 5) 0~10V
Output signal (channel 2) (code 6) 0~20mA
Output signal (channel 2) (code 7) Other customised signals
Power supply method (code default) Default 24VDC power supply
Power supply (code A) 220VAC power supply
  • Dual-channel two-in/two-out, two potentiometer signals each isolated and converted
  • The output signal types of the two channels are determined separately by the ordering code
  • Paired valve position feedback, dual-loop level indication for centralised installation
  • Configuration via PC or handheld programmer, online fault self-diagnostics
  • Conversion accuracy 0.1%F.S., temperature drift 30ppm/°C
  • 17.8 mm width, DIN rail mounting

Dual valve position feedback

Paired valve position feedback, dual-loop level indication and other dual-channel resistance signal transmission requiring centralised installation

Need selection advice or bulk quotation?

Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Inquire about the product

SC3037 · SC3037 电位器变送器(双通道)

Please enter the requirement description (at least 10 characters)

Online customer service
Online customer service Scan or click to contact directly
Contacts
Miss Chen(Safety barriers, isolators, surge protectors)
陈小姐 个人微信二维码

Scan WeChat QR code to add personal WeChat

QQ:2501529964

Phone:17717626508

Email:chenjing@qishan-sh.com

Miss Lu(Field Instruments, Valve Accessories, Terminal Blocks)
卢小姐 个人微信二维码

Scan WeChat QR code to add personal WeChat

QQ:1695457483

Phone:13636420802

Email:lhm@qishan-sh.com

Mr. Ye(Technical Support, After-Sales Service)

QQ:97010638

Phone:15800474322

Email:web@qishan-sh.com

Online Message

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address