SC3075 Temperature Transmitter (One-in Two-out)
Temperature transmitter one-in two-out: one temperature signal with two outputs, output 2 can be optionally RS485 communication, input type determined by the ordering code.
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
Same as SC3073, single-channel one-in two-out configuration, the signal types of the two outputs can be determined separately by the ordering code, output 2 can be optionally RS485 communication. Requires independent power supply, three-port isolation of input, output and power supply.
Note:Three-port isolation of input, output and power supply. 24V DC (or 220VAC) independent power supply; input side connected as thermocouple or RTD; output side includes output 1 and output 2, signal types determined separately by the ordering code (output 2 can be optionally RS485 communication). Configurable via PC or handheld programmer. Module indicators: green power indicator, red fault signal. All terminals are hot-swappable. Refer to the silkscreen on the module side for specific terminal numbers.
Ordering information:
- The sensor type, two output signals and power supply method must be specified when ordering.
- Factory example: Pt100 input, two 1-5V outputs, model SC3075-22.
| Parameter Name | Technical Specifications |
|---|---|
| Power supply and power consumption | |
| Power Supply | 18V DC~60V DC (independently powered products); 85V AC~265V AC (90V DC~360V DC) |
| Power consumption | ≤0.8W (24V, single-channel full-load output); ≤0.8W (220V, single-channel full-load output) |
| Input characteristics | |
| Input Signal | Thermocouples such as K, E, S, B, J, T, R, N; RTDs such as Pt100, Cu100, Cu50, BA1, BA2 |
| Lead resistance | ≤20Ω/wire (RTD) |
| Output and load | |
| Output Signal | Current: 0/4–20mA, 0–10mA; Voltage: 0/1–5V, 0–10V |
| Permissible load | 0/4~20mA: RL≤550Ω, 0~10mA: RL≤1.1kΩ; 0/1~5V: RL≥1MΩ, 0~10V: RL≥2MΩ |
| Accuracy and response | |
| Compensation accuracy | 1℃ (compensation temperature range: -20℃ to +60℃) |
| Temperature drift | 30ppm/℃ |
| Response time | ≤500ms |
| Isolation and electromagnetic compatibility | |
| Electromagnetic compatibility | IEC 61326-3-1 |
| Dielectric strength | ≥1500V AC (between input/output/power supply) |
| Insulation resistance | ≥100MΩ (between input/output/power supply) |
| Communication and Transmission | |
| Communication Parameters | MODBUS-RTU, distance ≤1000m, number of nodes ≤32 |
| Baud Rate | ≤19.2kbps |
| Environmental and Mechanical | |
| IP Protection | IP20 |
| Operating Temperature | -20℃~+60℃ |
| Storage Temperature | -40℃~+80℃ |
| Dimensions | 12.8mm×110mm×117mm (W×H×D) |
| Product Selection Code | |
| Output signal 1 (code 1) | 4-20mA (default is 4-20mA) |
| Output signal 1 (code 2) | 1~5V |
| Output signal 1 (code 3) | 0~10mA |
| Output signal 1 (code 4) | 0~5V |
| Output signal 1 (code 5) | 0~10V |
| Output signal 1 (code 6) | 0~20mA |
| Output signal 2 (code 1) | 4-20mA (default is 4-20mA) |
| Output signal 2 (code 2) | 1~5V |
| Output signal 2 (code 3) | 0~10mA |
| Output signal 2 (code 4) | 0~5V |
| Output signal 2 (code 5) | 0~10V |
| Output signal 2 (code 6) | 0~20mA |
| Output signal 2 (code 8) | RS485 |
| Input signal (code R) | RTD Input |
| Input signal (code T) | Thermocouple Input |
| Input signal (code default) | Default is full-function RTD and thermocouple input |
| Power supply method (code default) | Default 24VDC power supply |
| Power supply (code A) | 220VAC power supply |
- One input, two outputs; the two output types are determined by the ordering code respectively; output 2 can be RS485
- Input type selectable: RTD (R)/thermocouple (T) or full-function input
- Full thermocouple/RTD graduation support, cold junction compensation accuracy 1℃
- MODBUS-RTU communication, distance ≤1000m, number of nodes ≤32
- Configuration via PC or handheld programmer, online fault self-diagnostics
- DIN rail mounting, hot-swappable terminals
Temperature signal analogue + communication dual output
One temperature signal simultaneously outputs analogue and communication signals (e.g. 4-20mA to DCS, RS485 to network); or two outputs of different forms to different systems
Need selection advice or bulk quotation?
Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.
- Phone consultation +86-21-66020232
- Email inquiry web@qishan-sh.com