SC3076 Temperature Transmitter (dual-channel)
Dual-channel temperature transmitter: two thermocouple/RTD signals are each isolated and transmitted; the dual channels support passive output and RS485 communication.
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
Dual-channel configuration: two thermocouple/RTD signals are each isolated and converted to current/voltage signals; the dual channels support passive output. Independent power supply is required, with three-port isolation between input, output and power, and online fault self-diagnostics.
Note:Three-port isolation between input, output and power. Independent 24V DC (or 220V AC) power supply; two inputs each connected as thermocouple or RTD; two outputs as 0/4–20mA (dual channels support passive) or voltage signals, with RS485 communication support. Configurable via PC or handheld programmer. Module indicators: green power indicator, red fault signal. All terminals are hot-swappable. Refer to the silkscreen on the module side for specific terminal numbers.
Ordering information:
- When ordering, specify the two sensor types, two output signals and power supply method.
- Factory example: two PT100 inputs, two 1-5V outputs, model SC3076-22.
| Parameter Name | Technical Specifications |
|---|---|
| Power supply and power consumption | |
| Power Supply | 18V DC~60V DC (independently powered products); 85V AC~265V AC (90V DC~360V DC) |
| Power consumption | ≤1.2W (24V, dual-channel full-load output); ≤2.5W (220V, dual-channel full-load output) |
| Input characteristics | |
| Input Signal | Thermocouples such as K, E, S, B, J, T, R, N; RTDs such as Pt100, Cu100, Cu50, BA1, BA2 |
| Lead resistance | ≤20Ω/wire (RTD) |
| Output and load | |
| Output Signal | Current: 0/4~20mA (dual channels support passive), 0~10mA; Voltage: 0/1~5V, 0~10V |
| Permissible load | 0/4~20mA: RL≤550Ω, 0~10mA: RL≤1.1kΩ; 0/1~5V: RL≥1MΩ, 0~10V: RL≥2MΩ |
| Accuracy and response | |
| Compensation accuracy | 1℃ (compensation temperature range: -20℃ to +60℃) |
| Temperature drift | 30ppm/℃ |
| Response time | ≤500ms |
| Isolation and electromagnetic compatibility | |
| Electromagnetic compatibility | IEC 61326-3-1 |
| Dielectric strength | ≥1500V AC (between input/output/power supply) |
| Insulation resistance | ≥100MΩ (between input/output/power supply) |
| Communication and Transmission | |
| Communication Parameters | RS-485; MODBUS-RTU, distance ≤1000m, nodes ≤32 |
| Baud Rate | ≤19.2kbps |
| Environmental and Mechanical | |
| IP Protection | IP20 |
| Operating Temperature | -20℃~+60℃ |
| Storage Temperature | -40℃~+80℃ |
| Dimensions | 17.8mm×110mm×117mm (W×H×D) |
| Product Selection Code | |
| Input Signal 1 (Code R) | RTD Input |
| Input Signal 1 (Code T) | Thermocouple Input |
| Input Signal 1 (Code Default) | Default is full-function RTD and thermocouple input |
| Input Signal 2 (Code Default) | Default is full-function RTD and thermocouple input |
| Input Signal 2 (Code R) | RTD Input |
| Input signal 2 (code T) | Thermocouple Input |
| Output signal 1 (code 1) | 4-20mA (default is 4-20mA) |
| Output signal 1 (code 2) | 1~5V |
| Output signal 1 (code 3) | 0~10mA |
| Output signal 1 (code 4) | 0~5V |
| Output signal 1 (code 5) | 0~10V |
| Output signal 1 (code 6) | 0~20mA |
| Output signal 2 (code 1) | 4-20mA (default is 4-20mA) |
| Output signal 2 (code 2) | 1~5V |
| Output signal 2 (code 3) | 0~10mA |
| Output signal 2 (code 4) | 0~5V |
| Output signal 2 (code 5) | 0~10V |
| Output signal 2 (code 6) | 0~20mA |
| Power supply method (code default) | Default 24VDC power supply |
| Power supply (code A) | 220VAC power supply |
- Dual-channel two-in two-out, two temperature signals isolated and transmitted separately
- Dual-channel 4-20mA supports passive output, with external loop power supply
- RS485 communication, MODBUS-RTU, distance ≤1000m, nodes ≤32
- Cold junction compensation accuracy 1°C, compensation range -20°C to +60°C
- Centralised transmission of dual temperature measurement points (e.g. equipment inlet and outlet temperatures)
- 17.8 mm width, DIN rail mounting
Centralised transmission of dual temperature measurement points
Centralised transmission of dual temperature measurement points (e.g. equipment inlet and outlet temperatures); for applications requiring passive output with external loop power supply