BB-200CF-3M Differential pH Electrode
The BB-200CF-3M uses a differential measurement structure; the reference circuit and measurement circuit are isolated from each other, and the output signal is insensitive to reference contamination, earth interference and common-mode potential, making it suitable for…
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
The BB-200CF-3M uses a differential measurement structure; the reference circuit and measurement circuit are isolated from each other, and the output signal is insensitive to reference contamination, earth interference and common-mode potential, making it suitable for pH measurement under harsh environmental conditions.
Selection Tips:A fallback solution for harsh environments and high-interference situations. The differential structure is insensitive to reference contamination, earth loops and common-mode potential; the range covers -2–14 pH and temperatures of -5–105°C, making it suitable for sites with dense VFDs, high motor interference or complex signal earthing.
Application Areas:Suitable for pH measurement under harsh environmental conditions; the differential measurement structure suppresses common-mode and earth interference; measuring range -2–14 pH, temperature range -5–105°C, pressure resistance 0.4MPa at 105°C.
Matching Instruments:BSP2100 / BSP2200 / BSP2200D (pH channel).
| Parameter Name | Technical Specifications |
|---|---|
| Measurement Performance | |
| Measurement Range | -2–14 pH |
| Temperature Compensation | |
| Temperature Range | -5~105℃ |
| Structure and Material | |
| Maximum pressure | 0.4MPa at 105°C |
| Installation Size | PG13.5 Thread |
| Application | Suitable for harsh environmental conditions |
- Differential measurement structure, strong interference immunity
- Range extended to -2–14 pH, covering strong acid and strong alkali conditions
- Temperature range -5–105°C, pressure resistance 0.4MPa (at 105°C)
- PG13.5 threaded mounting
Typical application scenarios
Suitable for pH measurement under harsh environmental conditions; the differential measurement structure suppresses common-mode and earth interference; measuring range -2–14 pH, temperature range -5–105°C, pressure resistance 0.4MPa at 105°C.