NS41 Frequency Transmitter
Input frequency pulse (0.1Hz–100kHz, range to be specified at ordering), isolated transmission output 0/4–20mA, 0/1–5V, 0/2–10V; one-in-one-out/one-in-two-out/one-in-three-out (alarm optional).
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
Frequency transmitter; the input frequency pulse signal is isolated and converted into a current or voltage signal output. Requires independent power supply, with three-port isolation between input, output and power supply, and online fault self-diagnostics; the frequency range and fault output mode can be configured via PC or handheld programmer.
| Parameter Name | Technical Specifications |
|---|---|
| Power supply and power consumption | |
| Power Supply | 18V DC–32V DC, power reverse protection; 85V AC–265V AC (90V DC–360V DC) |
| Power consumption | ≤0.8W (24V single-channel full load); ≤1.3W (24V dual-channel full load); ≤2.5W (220V dual-channel full load) |
| Input characteristics | |
| Input Signal | Frequency pulse signal (range to be specified at ordering) |
| Frequency range | 0.1Hz–100kHz |
| Pulse width | >5μs |
| Input Impedance | ≥10kΩ |
| Signal trigger | Low level 0V~2V, high level 4V~30V |
| Distribution voltage | 24V DC, output voltage ≥16V at 20mA |
| Output and load | |
| Output Signal | Current: 0/4–20mA (passive output supported with 220V power supply); voltage: 0/1–5V, 0/2–10V |
| Permissible load | Current RL≤550Ω; passive RL<[(U-3)/0.02]Ω; voltage RL≥1MΩ/≥2MΩ |
| Accuracy and response | |
| Conversion accuracy | 0.1%F.S. (25°C±2°C) |
| Temperature drift | 40ppm/°C |
| Response time | ≤500ms |
| Isolation and Environment | |
| Electromagnetic compatibility | IEC 61326-3-1 |
| Dielectric strength | ≥1500V AC (between input/output/power supply) |
| Insulation resistance | ≥100MΩ (between input/output/power supply) |
| Operating Temperature | -20°C~+60°C |
| Storage Temperature | -40°C~+80°C |
- Frequency pulse 0.1Hz–100kHz wide-range input
- Isolated transmission to standard current/voltage signal
- DIN-rail mounting, three-way isolation of input, output and power supply, dielectric strength ≥1500V AC, EMC IEC 61326-3-1.
Isolated transmission of flowmeter pulse signal
Conversion of vortex/turbine flowmeter pulse frequency signal to 4-20mA for connection to DCS, enabling remote flow transmission
Need selection advice or bulk quotation?
Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.
- Phone consultation +86-21-66020232
- Email inquiry web@qishan-sh.com