NS42 Frequency Repeater

Product Model NS42

Product Brand

Product Category Industrial safety and signal conditioning modules / signal isolators, industrial safety and signal conditioning modules

Application Industry Petrochemical, process automation

Input frequency pulses (≤100kHz), 1:1 isolated frequency output (logic level/open collector selectable); one-in-one-out NS42, one-in-two-out NS42-C.

Inquire Now
  • Original Factory Genuine, Tenfold Compensation for Counterfeits
  • Full Machine Warranty, Lifetime Maintenance
  • In Stock, Shipped on the Same Day

Frequency repeater: input frequency pulse signals, isolated and converted to 1:1 frequency signals (logic level output by default; collector output and emitter output selectable) for output. Requires independent power supply; input, output and power supply are three-way isolated.

NS42 Frequency Repeater Technical Specifications
Parameter Name Technical Specifications
Power supply and power consumption
Power Supply 18V DC~32V DC, power reverse protection
Power consumption ≤0.9W (24V single output); ≤1.8W (24V dual output)
Input characteristics
Input Signal Frequency pulse signal
Frequency range ≤100kHz
Pulse width >5μs
Signal trigger Low level 0V~2V, high level 4V~30V
Distribution voltage 24V DC, output voltage ≥16V at 20mA
Output and load
Output Signal Logic level (default) or open collector
Logic level output High level 18≤VH≤24V, low level VL≤2V, drive current≤10mA, load resistance≥2kΩ
Open collector output High level Vcc (≤30V), low level V≤2V, drive current≤10mA, load resistance≥2kΩ
Isolation and Environment
Electromagnetic compatibility IEC 61326-3-1
Dielectric strength ≥1500V AC (between input/output/power supply)
Insulation resistance ≥100MΩ (between input/output/power supply)
Operating Temperature -20°C~+60°C
Storage Temperature -40°C~+80°C
  • Frequency signal 1:1 isolated repeater
  • Logic level/open collector output selectable
  • DIN-rail mounting, three-way isolation of input, output and power supply, dielectric strength ≥1500V AC, EMC IEC 61326-3-1.

Flowmeter pulse signal 1:1 repeater

Flowmeter pulse signal isolated and transmitted as-is to the frequency acquisition card, eliminating common-ground interference

Need selection advice or bulk quotation?

Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Inquire about the product

NS42 · NS42 Frequency Repeater

Please enter the requirement description (at least 10 characters)

Online customer service
Online customer service Scan or click to contact directly
Contacts
Miss Chen(Safety barriers, isolators, surge protectors)
陈小姐 个人微信二维码

Scan WeChat QR code to add personal WeChat

QQ:2501529964

Phone:17717626508

Email:chenjing@qishan-sh.com

Miss Lu(Field Instruments, Valve Accessories, Terminal Blocks)
卢小姐 个人微信二维码

Scan WeChat QR code to add personal WeChat

QQ:1695457483

Phone:13636420802

Email:lhm@qishan-sh.com

Mr. Ye(Technical Support, After-Sales Service)

QQ:97010638

Phone:15800474322

Email:web@qishan-sh.com

Online Message

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Please enter the requirement description (at least 10 characters)