Thermocouples (RTDs) for Power Industry
Thermocouples (RTDs) dedicated to high-temperature and high-pressure measurement for power station boilers, main steam pipelines and thermal systems, with deep blind-hole protection tubes and spring-loaded compression structure.
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
Thermocouples (RTDs) for power station temperature measurement are mainly used to measure the temperature of steam pipelines and boilers, employing a combination of protection tube and sheathed thermocouple (RTD). Users can weld or mechanically fix the protection tube to the equipment, then insert the sheathed element to operate, which not only increases the working pressure and service life but also facilitates maintenance or replacement. The products are available in five structural forms: thermowell type, air duct and flue duct type, high pressure, medium pressure and low pressure, and can be selected according to temperature, pressure and steam flow rate.
| Parameter Name | Technical Specifications |
|---|---|
| Main Technical Specifications of Thermocouples | |
| Structure type | Five types: thermowell / air duct and flue duct / high pressure / medium pressure / low pressure |
| Graduation | K / E |
| Measurement Range | 0~650℃; air duct and flue duct type 0~1000℃ |
| Class 1 tolerance | ±1.5℃ or ±0.4%|t| |
| Class 2 tolerance | ±2.5℃ or ±0.75%|t| |
| Nominal pressure | 29.4(42) / 14.7 / 9.8(14.7) / 4 MPa |
| Permissible flow velocity | <80 / <30 / <9 / <9(30) m/s |
| Thermal response time τ0.5 | <180s (duct/flue type <90s) |
| Protection tube material | F91 / F92 / 304 / 310S / 316 |
| Main Technical Specifications of RTDs | |
| Graduation | Pt100 |
| Measurement Range | 0~600℃ |
| Class A tolerance | ±(0.15+0.2%|t|) |
| Class B tolerance | ±(0.3+0.5%|t|) |
- Protection tube machined as a single piece using deep blind hole technology, with no welding at the end, for higher strength and longer service life
- Sheathed element adopts a spring-loaded structure, maintaining good contact with the measuring end of the protection tube during operation
- Vibration-resistant, reducing thermal response time
- Sheathed element adopts an insulated design to prevent electromagnetic interference, ensuring stable and accurate measurement
- Protection tube can be welded or mechanically fixed; the sensing element is easy to service and replace
Temperature measurement of main steam piping in power plants
The protection tube and sheathed element combination withstands high-temperature, high-pressure steam erosion, and supports servicing or replacement of the sensing element during operation.
Temperature measurement of boiler air ducts and flue ducts
The air duct and flue duct type structure is used for flue gas temperature monitoring under 0~1000℃ and flow velocity <9 m/s conditions.
Need selection advice or bulk quotation?
Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.
- Phone consultation +86-21-66020232
- Email inquiry web@qishan-sh.com