CXT Series Smart Pressure Transmitter
Single-crystal silicon composite pressure sensor smart transmitter, basic accuracy ±0.05%FS, turndown ratio up to 100:1, supports HART/FF/PA bus and SIL certification.
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
The core of the CXT Series high-accuracy smart transmitter adopts a unique monocrystalline silicon composite pressure sensor, an advanced integral capsule structure and the latest microprocessor technology, ensuring sensor stability and excellent performance. Basic accuracy ±0.05%FS (up to ±0.035%FS); field-proven over many years, it still achieves 0.05% accuracy after 10 years of continuous use.
The product features a rugged metal housing and highly reliable industrial-grade measuring components, with electromagnetic interference immunity and lightning protection; integrated diagnostics monitor the operating process and its own status in real time, entering an alarm state and outputting an alarm current once a set number of events is exceeded, providing control signals for system interlocking or SIS safety systems. It supports configuration via HART, PA, FF, APL and other communication protocols; the isolating diaphragm is available in various corrosion-resistant materials such as 316L, Hastelloy, tantalum, Monel 400, nickel, titanium or gold-plated 316L.
| Parameter Name | Technical Specifications |
|---|---|
| Accuracy and Range | |
| Basic accuracy | ±0.05%FS (up to ±0.035%FS) |
| Turndown ratio | SKC/SKG/SKA/SKP/SKH types 100:1; SKE/SKD/SKB/SKQ/SKR types 30:1 |
| Measuring range | Differential pressure 0~100Pa~14MPa; pressure -100kPa~1kPa~70MPa |
| Overload limit | Differential pressure 42MPa; pressure 100MPa |
| Long-term drift | ≤±0.1%FS/10 years |
| Temperature effect | ±(0.01% + 0.06% maximum range/operating range)/28℃ |
| Output and Communication | |
| Standard output | (4~20)mA DC with superimposed HART protocol (version 7.0) |
| Bus communication | PROFIBUS-PA (3.02), FF (6.5.0), APL, WirelessHART |
| Response time | Better than 90ms (sampled data refresh 60ms) |
| Environment and Protection | |
| Ambient Temperature | (-40~85)℃ (for explosion-proof types, see explosion-proof rating) |
| Process temperature | (-130~700)℃ |
| Relative Humidity | (5~100)%RH @40℃ |
| LCD temperature | (-40~80)℃ |
| Degree of protection | IP66 / IP67 / IP68 |
| Dielectric strength | 500VAC 50/60Hz, no breakdown or flashover between circuit and ground for 1 minute |
| Insulation resistance | 500VDC, not less than 100MΩ |
| Vibration effect | ≤±0.1%FS (10~150Hz, amplitude 0.075mm, 9.8m/s², 30 minutes) |
| Lightning Protection | |
| Built-in surge protection | Built-in lightning protection at terminals, 4kV/6kV (1.2×50μs) |
| Permissible current | Maximum 3000A (8×20μs) |
| Series models | |
| Standard version | SKC micro differential pressure/differential pressure, SKG pressure, SKA absolute pressure, SKP direct-mount pressure, SKH direct-mount absolute pressure, SKE level pressure, SKD dual-flange remote-seal differential pressure, SKB single-flange remote-seal pressure, SKQ flanged pressure, SKR flanged absolute pressure |
| Special solution | SK-L electronic differential pressure measurement system, SKD-T/SKP-T submersible level transmitter, SK-M ultra-high temperature pressure transmitter, multi-variable flow transmitter |
| Bus version | FF / PA / APL / WirelessHART / 5G RedCap pressure transmitter |
| Material | |
| Isolating diaphragm | 316L, Hastelloy, tantalum, Monel 400 alloy, nickel, titanium, gold-plated 316L |
| Wetted parts | Chamber, drain/vent plug and insert barrel assembly can be fitted with corrosion-resistant materials to suit the medium |
- Basic accuracy ±0.05%FS, up to ±0.035%FS
- Turndown ratio up to 100:1, one unit covers a wide range
- Fastest response better than 90ms (sampling refresh 60ms)
- Integrated diagnostics, outputs alarm current on fault and displays the faulty component
- Supports HART 7.0, PROFIBUS-PA, FF, APL and WirelessHART configuration
- Built-in surge protection in terminal block (4kV/6kV, maximum 3000A)
- Isolating diaphragm available in various corrosion-resistant materials for corrosive conditions
- Certified to NEPSI, CCS, IEC explosion protection, EU explosion protection, EAC and SIL
Pressure measurement in petrochemical plants
Measures pressure/differential pressure on reactors, columns and pipelines, sends it to the DCS via HART and participates in interlocking.
SIS safety instrumented loop
Utilises transmitter fault alarm current and SIL certification capability to provide pressure signals for safety interlock systems.
Need selection advice or bulk quotation?
Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.
- Phone consultation +86-21-66020232