R5000 32-channel paperless recorder
32-channel large-screen paperless recorder, 32 universal inputs and 32 alarm outputs, supporting flow calculation, temperature/pressure compensation and storage expansion.
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
The R5000 paperless recorder features 32 universal analogue inputs, 32 alarm outputs and a 100mA power distribution output, enabling signal acquisition, display, processing, flow totalisation, recording, alarming and power distribution, suitable for large installations with concentrated measurement points.
The instrument adopts a large-screen display, supports rate alarms, flow calculation and temperature/pressure compensation, and printing functions; storage capacity is expandable, and remote monitoring is possible via RS-232C/RS-485 communication.
| Parameter Name | Technical Specifications |
|---|---|
| Channel configuration | |
| Analogue input | 32 channels |
| Analogue output | 8-channel |
| Relay output | 32 channels |
| Signal input | |
| Current | 4~20mA, 0~20mA |
| Voltage | -10~10V, 0~100mV |
| Thermistors | Pt100, JPt100, Cu50 |
| Thermocouples | B, E, J, K, S, T, N, R, EA-2, WRe5-26, WRe3-25, etc. |
| Accuracy and communication | |
| Measurement accuracy | ±0.2% |
| Sampling period | 1 s |
| Communication | RS232/RS485 |
| Power distribution | 24VDC, 100mA |
| Isolation | 400VAC between channels; 1500VAC between channel and ground |
| Power supply and environment | |
| Power Supply | AC (100~240) V, (47~63) Hz |
| Power dissipation | ≤30VA |
| Operating Temperature | (0~50)℃ |
| Relative Humidity | (10~85) %RH |
| Fuse specification | 250VAC/3A, slow-blow type |
| Dimensions | |
| Dimensions | 288mm×288mm×240mm |
| Hole size | 282mm×282mm |
| Mounting panel thickness | (1.5–8.0)mm |
- 32-channel universal analogue input, suitable for large installations with concentrated measurement points
- 32 alarm outputs, with independently configurable upper/lower alarm limits and rate-of-change alarms
- Flow calculation and temperature/pressure compensation, with flow totalisation support
- Large-screen display, multi-channel data monitoring on a single screen
- Expandable storage capacity for long-term historical data retention
- RS232/RS485 communication, supporting printing and remote monitoring
Centralised monitoring of large installations
32 universal inputs connect furnace temperature, pressure and flow measurement points; large-screen display with alarm output.
Metallurgical reheating furnace monitoring
Records the temperature of each reheating furnace zone and issues rate-of-change alarms to prevent excessive heating rates from damaging the furnace body.