Dwyer 605 Series Magnehelic® Differential Pressure Transmitter with Display
Differential pressure transmitter with mechanical indication, local pointer reading + two-wire 4-20mA output.
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
The 605 Series combines a Magnehelic mechanical gauge with a two-wire transmitter, providing local pointer indication while outputting a 4-20mA signal. Stability ±1% FS/year, 4-inch dial, 1/8″ NPT pressure connections, suitable for building HVAC and cleanroom applications requiring both local reading and remote transmission.
| Parameter Name | Technical Specifications |
|---|---|
| Main specifications | |
| Medium | Air and non-combustible, compatible gases |
| Material | Please consult factory |
| Accuracy | See model table |
| Stability | ±1% of full scale/year |
| Pressure limit | See model table |
| Temperature Range | 20~120°F (-6.67~48.9°C) |
| Process connection | 1/8" NPT female thread |
| Size | 4" (101.6 mm) dial, 5" (127 mm) OD x 2-11/16" (68.3 mm) |
| Weight | 1 lb, 12.6 oz (811 g) |
| Certification | CE. |
| Compensated temperature range | 32~120°F (0~48.9°C) |
| Temperature effect | ±0.025% of full scale/°F (0.045% FS/°C). Power supply |
| Power Supply | 10-35 VDC (2-wire) |
| Output Signal | 4 to 20 mA |
| Zero and span adjustment | Potentiometer with protection |
| Loop resistance | DC; max. 0-1250 Ω |
| Current consumption | DC; max. 38 mA |
| Electrical connection | Screw terminal block |
| Mounting position | Diaphragm in vertical orientation; consult factory for other orientations |
| Model selection | |
| Selection table | Published on the official website as a screenshot of the model selection table; for complete model numbers and ranges, see the official manual "605_i1.pdf" in the documentation package. |
- Magnehelic mechanical gauge for local indication with simultaneous 4-20 mA output
- Two-wire connection, rear terminals, simple installation
- Stability ±1% FS/year
- 1/8" NPT female, 4" (101.6 mm) dial
Local differential pressure display for building air conditioning
Displays filter differential pressure on the plant room wall while sending the signal to the BA system.
Applications requiring dual differential pressure functions in clean areas
Used where both on-site inspection readings and remote signal transmission are required.
Need selection advice or bulk quotation?
Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.
- Phone consultation +86-21-66020232
- Email inquiry web@qishan-sh.com