Dwyer RSM Series Room Status Monitor

Product Model RSM Series

Product Brand

Product Category Pressure instruments / Pressure/differential pressure gauges, pressure instruments

Application Industry Smart manufacturing, biopharmaceuticals

Room status monitor, monitors room positive/negative pressure and alarms, NEMA 1 (IP20) indoor type.

Inquire Now
  • Original Factory Genuine, Tenfold Compensation for Counterfeits
  • Full Machine Warranty, Lifetime Maintenance
  • In Stock, Shipped on the Same Day

The RSM Series Room Status Monitor is used for pressure monitoring and alarming in critical low differential pressure applications and can be configured to monitor positive or negative pressure in protected environments or hospital isolation rooms. The graphical interface allows setting of pressure, safety, calibration and alarm parameters; outputs are selectable as 4-20mA, 0-5VDC or 0-10VDC.

Dwyer RSM Series Room Status Monitor Technical Parameters
Parameter Name Technical Specifications
Main specifications
Medium Air or non-conductive non-explosive gases.
Accuracy ±0.5% FS.
Temperature limit 32 ~120°F (0 ~50°C).
Humidity limit 5~95%RH (non-condensing).
Thermal effect ±0.03% FS/ °F (± 0.05% FS/ °C).
Pressure limits ±15 in w.c. (±3.7 kPa).
Power Supply Order Code A (24 VAC): 18-32 VAC, 50-60 Hz. Order Code B (120 VAC): 85-265 VAC, 50-60 Hz. Main supply voltage fluctuations up to 10%.
Output Jumper selectable 4-20 mA (2-wire), 0-5 VDC (3-wire), or 0-10 VDC (3-wire).
Switch type SPST.
Electrical connection Pluggable terminal block
Process connection Barbed fitting, 3/16" ID tubing.
Enclosure NEMA 1 (IP20) indoor applications
Housing Flame-retardant plastic
Installation Mounts to a standard 4x4" double-gang metal electrical box using a plaster ring adapter
Size 8" H x 5.4" W x 1.8" D (20.3 H x 13.7 W x 4.1 D cm).
Weight 1.5 lb (680 g).
Communication BACnet MSTP ASC optional.
Certification CE, CSA (RSM only)
Model selection
Selection table Published on the official website as a screenshot of the selection table; for complete model numbers and ranges, see the official manual "RSM.i.pdf" in the documentation package.
  • Graphical interface for setting pressure, safety, calibration and alarm parameters
  • Output options: 4-20mA (two-wire), 0-5VDC or 0-10VDC
  • SPST switch output, connectable to alarm or interlock
  • Accuracy ±0.5% FS, pressure limit ±15 in w.c.

Negative pressure monitoring in hospital isolation rooms

Monitors isolation room negative pressure per CDC guidelines, with audible and visual alarm on exceeding limits.

Differential pressure monitoring in server rooms and laboratories

Monitors positive pressure in protected environments to prevent ingress of contaminants.

Need selection advice or bulk quotation?

Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Inquire about the product

RSM Series · Dwyer RSM Series Room Status Monitor

Please enter the requirement description (at least 10 characters)

Online customer service
Online customer service Scan or click to contact directly
Contacts
Miss Chen(Safety barriers, isolators, surge protectors)
Ms Chen Personal WeChat QR Code

Scan WeChat QR code to add personal WeChat

QQ:2501529964

Phone:17717626508

Email:chenjing@qishan-sh.com

Miss Lu(Field Instruments, Valve Accessories, Terminal Blocks)
Ms Lu Personal WeChat QR Code

Scan WeChat QR code to add personal WeChat

QQ:1695457483

Phone:13636420802

Email:lhm@qishan-sh.com

Mr. Ye(Technical Support, After-Sales Service)

QQ:97010638

Phone:15800474322

Email:web@qishan-sh.com

Online Message

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Please enter the requirement description (at least 10 characters)