ST500 Isolating Amplifier
Process control signal isolation and conversion, input 0/4~20 mA or 0/2~10 V, current/voltage output selectable, 22.5 mm DIN rail housing, three-port isolation, with transmitter supply.
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
Process control signal isolation and conversion, input 0/4~20 mA or 0/2~10 V, current/voltage output selectable, 22.5 mm DIN rail housing, three-port isolation, with transmitter supply.
Main specifications: accuracy ≤ 0.2 % (single range adjustment ≤ 0.1 %); supply voltage 100..265 V AC or 10.8..30 V AC/DC; degree of protection housing IP30, terminals IP20 according to BGV A3 5 10.8..30 V AC/DC.
| Parameter Name | Technical Specifications |
|---|---|
| Main specifications | |
| Supply voltage | 100..265 V AC or 10.8..30 V AC/DC |
| Frequency | 47..63 Hz |
| Power dissipation | < 3.5 VA |
| Operating Temperature | -10..+60 °C |
| Conformity | EN 61326-1:2013 |
| Current | 0/4..20 mA optional, Ri = 25 Ω |
| Voltage | 0/2..10 V DC optional, Ri approx. 40 kΩ, overload max. 100 V |
| Span | Adjustable approx. ± 5 % |
| Transmitter supply | Approx. 24 V DC, Ri approx. 150 Ω |
| Response time (T90) | Model 10: < 20 ms, max. frequency 18 Hz |
| Accuracy | ≤ 0.2 % (single range adjustment ≤ 0.1 %) |
| Connection | screw terminals, max. 2.5 mm² |
| Degree of protection | Housing IP30, terminals IP20 according to BGV A3 5 10.8..30 V AC/DC |
- Process control signal isolation and conversion, input 0/4~20 mA or 0/2~10 V, current/voltage output selectable, 22.5 mm DIN rail housing, three-port isolation, with transmitter supply.
- Accuracy: ≤ 0.2 % (single range adjustment ≤ 0.1 %)
- Supply voltage: 100..265 V AC or 10.8..30 V AC/DC
- Protection class: housing IP30, terminals IP20 according to BGV A3 5 10.8..30 V AC/DC
- Power consumption: < 3.5 VA
Control cabinet signal isolation
Install an isolator between the PLC and field instruments to break earth loops and suppress common-mode interference.
Hazardous area signal isolation
Intrinsically safe products are used for signal isolation and energy limitation between hazardous and safe areas.
Need selection advice or bulk quotation?
Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.
- Phone consultation +86-21-66020232
- Email inquiry web@qishan-sh.com