The three levels correspond topermitted fault countdiffer; the higher the level, the more faults it can withstand and the more hazardous the applicable area.
| Level | Fault condition | Applicable area | EPL | Typical scenario |
|---|---|---|---|---|
| Ex ia | Normal operation + two independent faults | Zone 0, Zone 1, Zone 2 | Ga | Liquid level inside tanks, locations with continuously present flammable gas |
| Ex ib | Normal operation + one fault | Zone 1, Zone 2 | Gb | Pump areas, compressor rooms, loading/unloading racks |
| Ex ic | Normal operation only (faults not counted) | Zone 2 | Gc | Well-ventilated locations where leakage is possible only for short periods |
The meaning of "two independent faults" is: even if two failures occur simultaneously in the circuit (for example, zener breakdown + short-circuited current-limiting resistor), the remaining protection can still limit the energy. This is also why ia-rated products often use dual voltage limiting and dual current limiting internally — not redundant over-engineering, but a standard requirement.
Common selection errors:Using ib-rated equipment in Zone 0. Zone 0 accepts only ia (or specific types such as Ex ma encapsulation, Ex op is). If the engineering drawings specify Zone 0 but the purchase order is placed for ib, this is a typical compliance defect and will be judged non-conforming at the acceptance stage.
Relationship between cost and rating:ia products have higher component counts and screening requirements than ib, and are typically 15%–30% more expensive. If the site is actually only Zone 2, using ia is over-design; conversely, using ib in Zone 0 is a safety gap. Determine the rating by zone, not by "the more expensive, the safer".