Temperature classes constrain themaximum surface temperature of the equipment: the maximum temperature of any surface of the equipment must not exceed 80% of the ignition temperature of the surrounding gas (special provisions apply outside T1–T5), and is graded T1–T6.
| Temperature class | Permissible maximum surface temperature of equipment | Corresponding gas ignition temperature range (example) |
|---|---|---|
| T1 | 450 ℃ | > 450 ℃ (e.g. methane 537 ℃) |
| T2 | 300 ℃ | > 300–450 ℃ |
| T3 | 200 ℃ | > 200–300 ℃ (e.g. petrol 220–280 ℃) |
| T4 | 135 ℃ | > 135–200 ℃ (e.g. acetaldehyde 140 ℃) |
| T5 | 100 ℃ | > 100–135 ℃ |
| T6 | 85 ℃ | > 85–100 ℃ (e.g. carbon disulfide 90 ℃) |
The coverage relationship is likewise one-way:T6 equipment can be used in all T1–T6 locations; T4 equipment can only be used in locations requiring T4 or lower (i.e. gases with an ignition temperature above 135 ℃).
The temperature class of intrinsically safe equipment is usually not the bottleneck:Intrinsically safe circuits have low power and limited surface temperature rise, so most intrinsically safe transmitters rated T4 or T5 are sufficient. What really requires attention isequipment installed in dust layersandinstruments with heating functions(e.g. heat-traced analysers), where dust accumulation can significantly raise the surface temperature.
Selection verification method:Check the autoignition temperature or ignition temperature in the medium's safety data sheet (SDS), determine the required class against the table above, then check the equipment nameplate. If the medium is unknown, treat it as the most stringent (T6); do not simply apply "T4, as used in similar plants before".