The correct order for selecting a temperature class is "check the medium → determine the class → verify the equipment", not the reverse.
- Check the ignition temperature of the medium: obtain it from the safety data sheet (SDS) or the standard's annex, and note the distinction between the definitions used for "ignition temperature" and "autoignition temperature";
- Determine the required class: the maximum surface temperature of the equipment must be below 80% of the medium's ignition temperature; on this basis assign it to one of T1–T6;
- Verify the equipment nameplate: the T class marked on the equipment must be "not lower than" the required class (i.e. the higher the number, the stricter);
- Calculate the actual temperature rise: special operating conditions (high-temperature environment, heat tracing, dust coverage) require verification against the manufacturer's temperature-rise curves; do not rely on the nameplate alone.
| Medium ignition temperature | Required class | Equipment options |
|---|---|---|
| > 450 ℃ | T1 | T1–T6 all acceptable |
| 200~300 ℃ | T3 | T3, T4, T5, T6 |
| 135~200 ℃ | T4 | T4, T5, T6 |
| 85~100 ℃ | T6 | T6 only |
Do not apply T-class ratings to dust atmospheres:Dust environments are usually marked directly with the maximum surface temperature (e.g. T135°C), and distinguish whether a dust layer is present. Applying the gas T4 logic to dust can easily underestimate the temperature rise caused by accumulated dust.
Specifics of intrinsically safe circuits:Intrinsically safe equipment has low power and low surface temperature rise, so the temperature class is often not the limiting factor. The real risk lies on theassociated apparatus side— safety barriers densely installed in cabinets with poor heat dissipation can cause cabinet temperatures to exceed 50 °C, affecting barrier accuracy and service life; ventilation must be calculated during cabinet design.