WHA-BLT-F9D0-N-A0-Z0-Ex1 Bullet WirelessHART Adapter
Mountable in Zone 0/20, suitable for Class I, II Division 1 hazardous areas, suitable for Class III hazardous areas, suitable for Class I Division 2 hazardous areas.
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
Pepperl+Fuchs WHA-BLT-F9D0-N-A0-Z0-Ex1 Bullet WirelessHART Adapter, mountable in Zone 0/20, suitable for Class I, II Division 1 hazardous areas, suitable for Class III hazardous areas, suitable for Class I Division 2 hazardous areas, provides an intrinsically safe circuit for intrinsically safe Ex i field devices.
Part of the HART Interface Devices series, used for communication access, signal tapping and commissioning configuration between DCS/PLC control systems and HART field instruments, supporting HART protocol (including WirelessHART) multiplexing, loop conversion and filtering, and compatible with mainstream barriers and termination boards.
| Parameter Name | Technical Specifications |
|---|---|
| Power Supply | |
| Rated Voltage | 7 … 30 V DC |
| Rated current | < 1 mA, max. 25 mA |
| Electrical Data | |
| Output current | 3.2 … 25 mA |
| Power supply | Loop power supply for field devices, voltage: 1 … 2.5 V DC, adjustable in steps, step size 0.5 V |
| Input | |
| Connection | - 5-core cable, length 600 mm, led out from NPT1/2 male thread, 1 external earth connection point |
| Protocol | HART 7.1, backward compatible |
| Number of devices | Up to 8 HART field devices (depending on installation method) |
| Output | |
| Interface | Internal antenna |
| Communication | WirelessHART technical specifications, physical layer: IEEE 802.15.4-2006, frequency band: 2.4 GHz (ISM licence-free band), max. transmit power: +10 dBm, outdoor transmission range: 235 m, communication standard: WirelessHART according to IEC 62591 |
| Directive conformity | |
| Radio and telecommunications terminal equipment | Use of 2.4 GHz devices is subject to local regulations; confirm that local regulations permit use of this product before commissioning. |
| Directive 2014/53/EU | EN 300 328 V2.1.1:2016, EN 301 489-1 V2.2.0:2017, EN 301 489-17 V3.2.0:2017 |
| FCC CFR47 Part 15 B/C | ANSI C63.4-2003, FCC ID: X89-WA1101 |
| Conformity | |
| Degree of protection | IEC 60529:2013 |
| Ambient Conditions | |
| Ambient Temperature | temperature class T5: −40 … 85 °C (−40 … 185 °F), temperature class T6: −40 … 75 °C (−40 … 167 °F) |
| Storage Temperature | −40 … 85 °C (−40 … 185 °F) |
| Relative Humidity | max. 100 % |
| Mechanical parameters | |
| Degree of protection | IP67 |
| Material | aluminium alloy, polyurethane stoving enamel |
| Weight | 460 g |
| Dimensions | 60.8 x 60.8 x 100 mm (l x w x h) |
| Height | 100 mm |
| diameter | 60.8 mm |
| Hazardous area application data | |
| EU Type Examination Certificate | FM 17 ATEX 0046 X |
| Marking | II 1G Ex ia IIC T6 … T5 Ga, Ex II 1D Ex ia IIIC T95°C Da |
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013, EN 60079-11:2012 |
| International approvals | |
| FM approval | FM 17 NUS 0010, FM 17 US 0191 X |
| Control drawing | 116-0425 (cFMus) |
| Certification scope | IS Class I, II, III, Division 1, Groups A-G, Class I, Zone 0, AEx ia IIC T6 … T5 Ga, Zone 20, AEx ia IIIC T95°C Da |
| CSA certification | FM 17 NCA 0004, FM 17 CA 0102 X |
| Certification scope | IS Class I, II, III, Division 1, Groups A-G, Ex ia IIC T6 … T5 Ga, Ex ia IIIC T95°C Da, associated apparatus [Ex ia] |
| IECEx certificate | IECEx FMG 17.0020X |
| IECEx marking | Ex ia IIC T6 … T5 Ga, Ex ia IIIC T95°C Da |
| Standards | IEC 60079-0:2011, IEC 60079-1:2014, IEC 60079-11:2011, IEC 60079-31:2013 |
| General information | |
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals and manuals within the applicable scope. For related information, see www.pepperl-fuchs.com. |
- Mountable in Zone 0/20
- Suitable for Class I, II Division 1 hazardous areas
- Suitable for Class III hazardous areas
- Suitable for Class I Division 2 hazardous areas
- Provides an intrinsically safe circuit for intrinsically safe Ex i field devices
- Die-cast aluminium enclosure
- Loop-powered
- Directly mounted on HART or 4…20 mA field devices
- Potted antenna
- Up to 8 field devices in multidrop mode
Petrochemical Plant
HART field instrument commissioning and configuration communication
Power Energy System
DCS system HART multiplexer access
Process Automation
HART signal filtering and tapping between control room and field instruments
Documents not uploaded. Please fill in the information row by row in the 'Product Details Field' panel under 'File Name | Download Address | File Size'.
Need selection advice or bulk quotation?
Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.
- Phone consultation +86-21-66020232
- Email inquiry web@qishan-sh.com