SC3011 switch input isolator (one in, one out, relay output)

Product Model SC3011

Product Brand

Product Category Industrial Safety and Signal Conditioning Module / Signal Isolator

Application Industry Petrochemical, process automation

Single-channel switch input isolator: dry contact/NAMUR proximity switch input, isolated and converted to relay output; three-port isolation, DIP switches configurable for same/inverted logic and line fault monitoring.

Inquire Now
  • Original Factory Genuine, Tenfold Compensation for Counterfeits
  • Full Machine Warranty, Lifetime Maintenance
  • In Stock, Shipped on the Same Day

Switch input isolator, input dry contact or NAMUR proximity switch signal, isolated and converted to relay/transistor output. DIP switches can be used to set output and input same-phase or inverted logic control (default same-phase), set line fault monitoring on or off (default on, LED flashes on line fault), and set the second output function (as relay/transistor output or as fault alarm output). This product requires independent power supply, with three-port isolation of input, output and power.

Note:Three-port isolation of input, output and power. 24V DC independent power supply (note polarity of power terminals, module has power reverse protection); input side connects to dry contact switch or NAMUR proximity switch; output side is relay contact, can drive ≤40mA load, allowable load 250VAC/2A or 30VDC/2A. Module indicators: green power indicator, red fault signal, yellow channel status. When line fault monitoring is on, input disconnection (≤50μA) or short circuit (≥6.5mA) will cause the output relay to open and the red indicator to flash. All terminals are hot-swappable. Specific terminal numbers are subject to the silkscreen on the module side.

Ordering information:

  • This product requires independent power supply (18V DC~32V DC), system power supply configuration must be confirmed when ordering.
  • Output logic (same-phase/inverted), line fault monitoring, and second output function are set via DIP switches, default: same-phase, fault monitoring on.
SC3011 Switch Input Isolator (one in, one out, relay output) Technical specifications
Parameter Name Technical Specifications
Power supply and power consumption
Power Supply 18V DC ~32V DC power reverse protection
Power consumption 1W
Input characteristics
Input Signal Dry contact or NAMUR proximity switch
Switching characteristics Input current>2.1mA, output relay closed, channel indicator yellow steady on; input current<1.2mA, output relay open, channel indicator yellow off
Open-circuit voltage Approx. 8.5V
Short-circuit current Approx. 8.5mA
Line fault Input current≤50μA, input wire break detected, output relay open; input current≥6.5mA, input short circuit detected, output relay open; channel indicator red flashing
Output and load
Output Signal Relay contacts
Permissible load 250VAC/2A or 30VDC/2A
Drive current ≤40mA
External voltage <40V DC
Switching frequency <20ms
Isolation and electromagnetic compatibility
Electromagnetic compatibility <10Hz
Dielectric strength ≥1500V AC (between input/output/power supply)
Insulation resistance ≥100MΩ (between input/output/power supply)
Environmental and Mechanical
IP Protection IP20
Operating Temperature -20℃~+60℃
Storage Temperature -40℃~+80℃
Dimensions 12.8mm×110mm×117mm (W×H×D)
DIP switch settings
DIP switch S1~S4 (module marked 51, 52, 53, 54): same-phase/inverted logic (default same-phase), line fault monitoring switch (default on), second output function (SC3012 is relay/transistor output or fault alarm output)
  • Dry contact or NAMUR proximity switch input, isolated and converted to relay contact output
  • DIP switches set same-phase/inverted logic (default same-phase), line fault monitoring (default on, LED flashes on fault)
  • Input disconnection (≤50μA)/short circuit (≥6.5mA) online monitoring, output opens and indicator flashes on fault
  • Three-port isolation of input, output and power, forming a fully floating system, no grounding required
  • Allowable load 250VAC/2A or 30VDC/2A, drive current ≤40mA
  • DIN rail mounting, hot-swappable terminals, 12.8mm compact width

Dry contact signal isolated connection to DCS/PLC

Dry contact (passive contact) or NAMUR proximity switch signal connected to DCS/PLC switch input channel, relay normally-open contact also serves as fault alarm output, electrical isolation between field and control room

Need selection advice or bulk quotation?

Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Inquire about the product

SC3011 · SC3011 开关量输入隔离器(一进一出,继电器输出)

Please enter the requirement description (at least 10 characters)

Online customer service
Online customer service Scan or click to contact directly
Contacts
Miss Chen(Safety barriers, isolators, surge protectors)
陈小姐 个人微信二维码

Scan WeChat QR code to add personal WeChat

QQ:2501529964

Phone:17717626508

Email:chenjing@qishan-sh.com

Miss Lu(Field Instruments, Valve Accessories, Terminal Blocks)
卢小姐 个人微信二维码

Scan WeChat QR code to add personal WeChat

QQ:1695457483

Phone:13636420802

Email:lhm@qishan-sh.com

Mr. Ye(Technical Support, After-Sales Service)

QQ:97010638

Phone:15800474322

Email:web@qishan-sh.com

Online Message

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Please enter the requirement description (at least 10 characters)