First confirm whether the safety conditions have been restored (whether the emergency stop has been reset, whether the safety door is closed, whether the light curtain is clear); then check the input circuit for broken wires or short circuits; then verify whether the reset terminal requires manual triggering; finally check whether a persistent fault is locking out the reset.
Do not force a reset or short-circuit the safety circuit before the fault has been cleared.