BB-220-3M Ultra-high Temperature Glass pH Electrode
The BB-220-3M is a reinforced solution for high-temperature conditions, with an upper temperature limit of 130°C, suitable for pH online monitoring in high-temperature sterilisation and acid-base applications, range 0~…
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
The BB-220-3M is a reinforced solution for high-temperature conditions, with an upper temperature limit of 130°C, suitable for pH online monitoring in high-temperature sterilisation and acid-base applications, range 0~14 pH.
Selection Tips:A reinforced solution with an upper temperature limit of 130°C, combining 0.4Mpa pressure resistance with an Ag/AgCl reference structure, suitable for harsh conditions of high-temperature sterilisation and alternating acid-base exposure. Along with high-temperature resistance, the strength of the electrode sheath material at the corresponding temperature must also be confirmed.
Application Areas:Suitable for high-temperature conditions and high-temperature sterilisation, acid-base applications; measuring range 0~14 pH, temperature range 0~130°C, pressure resistance 0.4Mpa.
Matching Instruments:BSP2100 / BSP2200 / BSP2200D (pH channel).
| Parameter Name | Technical Specifications |
|---|---|
| Measurement Performance | |
| Measurement Range | 0~14 pH |
| Temperature Compensation | |
| Temperature Range | 0~130℃ |
| Structure and Material | |
| Pressure Resistance | 0.4MPa |
| Material | Glass |
| Installation Size | PG13.5 Thread |
| Sheath Selection | Submersible Sheath or Pipeline Sheath |
| Reference Electrode | Ag/AgCl |
| Application | Suitable for high-temperature conditions, high-temperature sterilisation, and acid/alkali applications |
- Glass high-temperature construction, maximum operating temperature 130°C
- Ag/AgCl reference electrode
- Pressure resistance increased to 0.4MPa
- PG13.5 threaded mounting
Typical application scenarios
Suitable for high-temperature conditions and high-temperature sterilisation, acid-base applications; measuring range 0~14 pH, temperature range 0~130°C, pressure resistance 0.4Mpa.
Need selection advice or bulk quotation?
Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.
- Phone consultation +86-21-66020232
- Email inquiry web@qishan-sh.com



