BSX3200 Conductivity/Resistivity/Salinity/TDS Analyzer
The BSX3200 adds a salinity measurement channel and a second current output to the BSX2100, and features electrode cleaning timer settings, relay delay action and multi-function…
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
The BSX3200 adds a salinity measurement channel and a second current output to the BSX2100, and features electrode cleaning timer settings, relay delay action and multi-function relays (cleaning/expiry alarm/error alarm), making it suitable for seawater desalination, multi-channel conductivity monitoring and applications requiring periodic cleaning and maintenance.
Application Areas:Suitable for water treatment plants, hospital wastewater treatment, purified water, boiler water, surface water, seawater desalination, electroplating, electronics, chemicals, pharmaceuticals, food, fermentation, breweries, aquaculture, etc. ## IV. pH / ORP measurement electrodes
| Parameter Name | Technical Specifications |
|---|---|
| Measurement Performance | |
| Measurement Range | Conductivity: 0.00 μS–2000 mS; resistivity: 0.00–20.00 MΩ-CM; salinity: 0.00–78.00 g/kg; TDS: -0–+133000 ppm |
| Measurement Resolution | Conductivity: 0.01/0.1/1; resistivity: 0.01; salinity: 0.01; TDS: 1 |
| Measurement Accuracy | ±1%F.S. |
| Temperature Compensation | |
| Temperature Compensation Method | PT1000/NTC30K |
| Temperature Measurement Range | -10.0~+130.0℃ |
| Temperature Resolution | 0.1℃ |
| Temperature Accuracy | ±0.2℃ |
| Temperature Compensation | 0.00~40.00 |
| Output to Relay | |
| Current Output Accuracy | ±0.05mA |
| Relay Contact Capacity | 5A/250VAC, 5A/30VDC |
| Current output 1 | Isolated 4-20mA Output, Maximum Load 500Ω |
| Current output 2 | Isolated 4-20mA Output, Maximum Load 500Ω |
| Current output accuracy | ±0.05mA |
| Relay Contact Capacity | 5A/250VAC, 5A/30VDC |
| Cleaning setting | ON 1–1000 s / OFF 0.1–1000.0 h |
| One multi-function relay | Cleaning/Overdue Alarm/Error Alarm |
| Relay Delay Action | 0-120 seconds |
| Environment and Installation | |
| Operating Environment Temperature | 0~70.0℃ |
| Storage Environment Temperature | -20~70.0℃ |
| Power Supply | 90-260Vac, Power Consumption <5W |
| Installation Method | Panel Mounting/ Wall Mounting/Pipe Mounting |
- Protection Class IP65, Suitable for Outdoor Use
- Backlit dot matrix LCD, simple setup and calibration process
- Two-channel relay control
- Two-channel current 4~20mA output
- RS485 Modbus RTU standard protocol, convenient for remote monitoring and communication via computer
- Current and relay test functions
- Multiple language options: Simplified Chinese, Traditional Chinese, English
- Four-pole circuit design, can use four-pole or two-pole electrodes
Typical application scenarios
Suitable for water treatment plants, hospital wastewater treatment, purified water, boiler water, surface water, seawater desalination, electroplating, electronics, chemicals, pharmaceuticals, food, fermentation, breweries, aquaculture, etc. ## IV. pH / ORP measurement electrodes
Need selection advice or bulk quotation?
Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.
- Phone consultation +86-21-66020232
- Email inquiry web@qishan-sh.com