Dwyer RPMC StabiliSENSE™ Intensive Care Room Pressure Monitor
StabiliSENSE intensive care room pressure monitor, ±0.25% RSS, stainless steel panel for easy cleaning and disinfection.
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
The RPMC StabiliSENSE ICU pressure monitor uses a capacitive sensor with ±0.25% RSS accuracy, designed specifically for stringent pressure monitoring and alarm applications. The brushed stainless steel panel facilitates repeated cleaning and disinfection, 4-20mA output, and push-button menu for zero and span setting.
| Parameter Name | Technical Specifications |
|---|---|
| Main specifications | |
| Medium | Air and non-combustible compatible gases. |
| Measurement technology | Capacitive cell. |
| Wetted materials | Consult factory. |
| Enclosure material | Die-cast aluminium housing and stainless steel bezel. |
| Accuracy | ±0.25% RSS (including non-linearity: ±0.24%, |
| Hysteresis | ±0.05% and non- |
| Repeatability | ±0.05%), or ±0.5% RSS (including non-linearity: ±0.49%, |
| Pressure limits | 2 psig. |
| Temperature limit | 32~140°F (0~60°C). |
| Temperature compensation limits | 32~140°F (0~60°C). |
| Thermal effect | 0.030%/°F (0.050/°C) at 77°F (25°C). |
| Power Supply | 12-28 VDC, 12-28 VAC 50 to 400 Hz. |
| Power dissipation | 3 VA max. |
| Output | 4-20 mA DC, loop impedance not exceeding 900 Ω. |
| Zero and span adjustment | Push-buttons and menu. |
| Display | Backlit 4-digit LCD 0.4" high, LED indicators for setpoint and alarm status. |
| Electrical connection | 15-pin male high-density D-sub connector. Includes 18-inch (46 cm) cable with 10 conductors. |
| Process connection | 1/8" NPT female. Side or rear connection. |
| Mounting orientation | Vertical. Surface diameter: 4-3/4" (120.7 mm) OD x 2-21/32 (67.5 mm). |
| Weight | 1.90 lb (862 g). |
| Model selection | |
| Selection table | Published on the official website as a screenshot of the selection table; for complete model numbers and ranges, see the official manual "RPMC_i.pdf" in the documentation package. |
- Capacitive sensor, accuracy ±0.25% RSS
- Brushed stainless steel panel, repeatedly wipeable and disinfectable
- Backlit 4-digit LCD + LED setpoint and alarm indication
- 4-20mA output, 12-28 VDC/VAC supply
- Push-button menu for zero and span setting
Intensive care unit negative pressure monitoring
Continuous monitoring of ICU negative pressure ward differential pressure, with over-limit alarm.
Clean manufacturing area positive pressure monitoring
Monitors clean area positive pressure to prevent ingress of external contamination.
Need selection advice or bulk quotation?
Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.
- Phone consultation +86-21-66020232
- Email inquiry web@qishan-sh.com