FI-PFH-TR-AO-380X 8-Channel Communication Board
System board for Schneider Electric Triconex Tricon series, HART termination panel (ETP) for Tricon AO modules, suitable for 8-channel AO card 3805E, 8 channels.
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
Pepperl+Fuchs FI-PFH-TR-AO-380X Communication Board, system board for Schneider Electric Triconex Tricon series, HART termination panel (ETP) for Tricon AO modules, suitable for 8-channel AO card 3805E, 8 channels, field side: pluggable screw terminals, green.
Part of the HART Interface Devices series, used for communication access, signal tapping and commissioning configuration between DCS/PLC control systems and HART field instruments, supporting HART protocol (including WirelessHART) multiplexing, loop conversion and filtering, and compatible with mainstream barriers and termination boards.
| Parameter Name | Technical Specifications |
|---|---|
| Power Supply | |
| Rated Voltage | 25 … 28 V DC SELV/PELV |
| Ripple | max. 10 % |
| Fuse protected | 1 A |
| Power dissipation | ≤ 500 mW |
| Interface | |
| Type | Multiplexer connection: IDC plug, 26-pin |
| Redundant | |
| Power supply | Redundancy available. The supply is monitored and fused. |
| Signal lines | |
| Rated current | Max. 30 mA per channel |
| Indication/setting | |
| Display elements | - LED PS-A (Termination Board power supply), green LED, LED PS-B (Termination Board power supply), green LED |
| Directive conformity | |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
| Conformity | |
| Electromagnetic compatibility | NE 21:2017, see system description |
| Degree of protection | IEC 60529:2001 |
| Shock resistance | EN 60068-2-27 |
| Vibration Resistance | EN 60068-2-6 |
| Ambient Conditions | |
| Ambient Temperature | 0 … 50 °C (32 … 122 °F) |
| Storage Temperature | −15 … 50 °C (5 … 122 °F) |
| Relative Humidity | ≤93%, non-condensing |
| Shock resistance | 15 g, 11 ms |
| Vibration Resistance | 1 g, 10 … 150 Hz |
| Mechanical parameters | |
| Degree of protection | IP20 |
| Field side | pluggable screw terminal, green |
| Control side | ELCO socket, 56-pin, HART: 2 x IDC plug, 26-pin |
| Power supply | Screw terminal, green |
| Core cross-section | 0.5 … 2.5 mm2 (20 … 12 AWG) |
| Housing | PVC |
| Weight | approx. 300 g |
| Dimensions | 126 x 123 x 59 mm (5.0 x 4.9 x 2.3 inch) (W × H × D) |
| Installation Method | Mounts on 35 mm DIN mounting rail in accordance with EN 60715:2001 |
| Hazardous area application data | |
| Certificate | PF 11 CERT 1933 X |
| Marking | II 3G Ex nA IIC T4 Gc |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020, EN 60079-15:2010 |
| General information | |
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals and manuals within the applicable scope. For related information, see www.pepperl-fuchs.com. |
- System board for Schneider Electric Triconex series Tricon
- HART termination board (ETP) for Tricon AO modules
- Suitable for 8-channel AO card 3805E
- 8-channel
- Field side: pluggable screw terminals, green
- Control side: ELCO socket, 56-pin
Petrochemical Plant
HART field instrument commissioning and configuration communication
Power Energy System
DCS system HART multiplexer access
Process Automation
HART signal filtering and tapping between control room and field instruments
Documents not uploaded. Please fill in the information row by row in the 'Product Details Field' panel under 'File Name | Download Address | File Size'.
Need selection advice or bulk quotation?
Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.
- Phone consultation +86-21-66020232
- Email inquiry web@qishan-sh.com