GLMU200 Conductivity Transmitter (Pure Water Type)
Two-electrode sensor, suitable for pure water, drinking water and fresh water, range 0.1 μS/cm~200.0 mS/cm, LCD display, output 4~20 mA or 0~10 V.
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
Two-electrode sensor, suitable for pure water, drinking water and fresh water, range 0.1 μS/cm~200.0 mS/cm, LCD display, output 4~20 mA or 0~10 V.
Main specifications: accuracy 0.3 % FS; protection rating IP65.
| Parameter Name | Technical Specifications |
|---|---|
| Main specifications | |
| Range | 0...200 mS/cm |
| Accuracy | 0.3 % FS |
| Temperature | -5...+140 °C |
| Electrode constant | For LFE-202 for drinking/fresh water: 1 1/cm; For LFE-230 for drink/fresh water, screw-in measuring cell: 0.9 1/cm; For LFE-240 for ultrapure water: 0.1 1/cm; For LFE-220 for ultrapure water, screw-in measuring cell: 0.1 1/cm |
| Degree of protection | IP65 |
| Operating Temperature | -25...+50 °C |
| Storage temperature | -25...+70 °C |
| Dimensions | 82 mm x 80 mm x 55 mm |
| Material | ABS |
| Installation Method | Field |
| Conformity | Yes |
| Connection | For LFE-202 for drinking/fresh water: Fixed cable connection; For LFE-230 for drink/fresh water, screw-in measuring cell: M12 8-pole circular connector; For LFE-240 for ultrapure water: Fixed cable connection; For LFE-220 for ultrapure water, screw-in measuring cell: M12 8-pole circular connector |
| Display type | LCD |
| Type | 3 Button |
| Auxiliary power supply | For 4 ... 20 mA: 12...30 V; For 0 ... 10 V: 18...30 V |
| Load | For 4 ... 20 mA: RA(Ohm) < ( (Uv – 12 V) / 0.02 A ); For 0 ... 10 V: > 3000 Ohm |
| Output | For 4 ... 20 mA: 4…20 mA two-wire; For 0 ... 10 V: 0…10 V three-wire |
| Cable | For 1 m: 1 m; For 2 m: 2 m; For 3 m: 3 m; For 4 m: 4 m; For 5 m: 5 m; For 6 m: 6 m; For 2 m: 2 m; For 5 m: 5 m; For 6 m: 6 m |
| Process connection | For LFE-202 for drinking/fresh water: without, PG13.5; For LFE-230 for drink/fresh water, screw-in measuring cell: G ½"; For LFE-240 for ultrapure water: without; For LFE-220 for ultrapure water, screw-in measuring cell: G ½" |
- Two-electrode sensor, suitable for pure water, drinking water and fresh water, range 0.1 μS/cm~200.0 mS/cm, LCD display, output 4~20 mA or 0~10 V.
- Output: For 4 ... 20 mA: 4…20 mA two-wire; For 0 ... 10 V: 0…10 V three-wire
- Accuracy: 0.3 % FS
- Protection class: IP65
Boiler feedwater and condensate monitoring
Online conductivity monitoring to detect water quality deterioration and condenser leakage.
Pure water production line monitoring
Monitor conductivity/resistivity at reverse osmosis and EDI outlets to ensure effluent compliance.
No documents uploaded yet.
Need selection advice or bulk quotation?
Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.
- Phone consultation +86-21-66020232
- Email inquiry web@qishan-sh.com