HiATB01-HART-2X16 32-channel HART communication board
32 channels, 24 V DC supply, for HART communication, dual RS 485 connection.
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
Pepperl+Fuchs HiATB01-HART-2X16 HART communication board, 32-channel, 24 V DC powered, suitable for HART communication, dual RS 485 connection, for use with HiC termination board.
Part of the HART Interface Devices series, used for communication access, signal tapping and commissioning configuration between DCS/PLC control systems and HART field instruments, supporting HART protocol (including WirelessHART) multiplexing, loop conversion and filtering, and compatible with mainstream barriers and termination boards.
| Parameter Name | Technical Specifications |
|---|---|
| Power Supply | |
| Connection | X20: terminals 1, 3(+); 2, 4(-) |
| Rated Voltage | 24 V DC SELV/PELV |
| Voltage drop | 0.9 V, voltage drop of series diode on termination board must be considered |
| Ripple | ≤ 10 % |
| Fuse protected | 0.5 A |
| Power dissipation | ≤ 500 mW, (excluding module) |
| Reverse polarity protection | 是 |
| Interface | |
| Type/number | 2 x RS-485 |
| Redundant | |
| Power supply | Redundancy available. The supply is decoupled, monitored and fused. |
| Indication/setting | |
| Display elements | LED PWR1 (termination board power supply), green LED, LED PWR2 (termination board power supply), green LED |
| Directive conformity | |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
| Conformity | |
| Electromagnetic compatibility | NE 21:2012, see system description |
| Degree of protection | IEC 60529:2001 |
| Ambient Conditions | |
| Ambient Temperature | −20 … 60 °C (−4 … 140 °F) |
| Storage Temperature | −40 … 70 °C (−40 … 158 °F) |
| Mechanical parameters | |
| Degree of protection | IP20 |
| Control side | RS-485 : 1 x screw terminal, black, HART : 2 x IDC plug, 34-pin |
| Power supply | pluggable screw terminal, black |
| Core cross-section | Screw terminal: 0.25 … 1.5 mm2 (24 … 12 AWG) |
| Material | Housing: polycarbonate, 10% glass fibre reinforced |
| Weight | Approx. 190 g |
| Dimensions | 50 x 200 x 163 mm (1.97 x 7.9 x 6.42 inch) (W × H × D), depth including module components |
| Installation Method | Mounts on 35 mm DIN mounting rail in accordance with EN 60715:2001 |
| General information | |
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals and manuals within the applicable scope. For related information, see www.pepperl-fuchs.com. |
- 32 channels
- 24 V DC supply
- Suitable for HART communication
- Dual RS 485 connection
- For use with HiC termination board
- Power status LED indicator
Petrochemical Plant
HART field instrument commissioning and configuration communication
Power Energy System
DCS system HART multiplexer access
Process Automation
HART signal filtering and tapping between control room and field instruments
Documents not uploaded. Please fill in the information row by row in the 'Product Details Field' panel under 'File Name | Download Address | File Size'.
Need selection advice or bulk quotation?
Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.
- Phone consultation +86-21-66020232