HM-PF-RS232-010001 Viator RS-232 HART Interface
Windows® 7, 10 and 11 compatible, HART compliant, communicates with any HART field device and performs error-free slave testing, easy to install, powered by the RS-232 port, no external power supply required for the modem.
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
Pepperl+Fuchs HM-PF-RS232-010001 Viator RS-232 HART interface, Windows® 7, 10 and 11 compatible, HART compliant, communicates with any HART field device and performs error-free slave testing, easy to install, powered by the RS-232 port, no external power supply required for the modem, compact and rugged polycarbonate housing, industrial-grade reliability.
Part of the HART Interface Devices series, used for communication access, signal tapping and commissioning configuration between DCS/PLC control systems and HART field instruments, supporting HART protocol (including WirelessHART) multiplexing, loop conversion and filtering, and compatible with mainstream barriers and termination boards.
| Parameter Name | Technical Specifications |
|---|---|
| Power Supply | |
| Input current | 4 mA |
| Power Supply | 4 … 12 V, powered by DTR and RS-232 inputs, No external power required |
| Interface | |
| Interface type | RS-232 port |
| Output | |
| Signal | 0.5 ± 0.1 Vpp trapezoidal wave at 1200/2200 Hz |
| Electrical Isolation | |
| Output/Interface | 1500 V DC |
| Directive conformity | |
| Directive 2014/30/EU | EN 61326-1:2013, EN 62368-1:2014-08 |
| Directive 2011/65/EU (RoHS) | EN IEC 63000:2018 |
| System requirements | |
| Operating system | Windows® 7, 10 and 11 or any operating system that supports serial COM ports |
| Ambient Conditions | |
| Operating Temperature | −20 … 50 °C (−4 … 122 °F) |
| Storage Temperature | −20 … 60 °C (−4 … 140 °F) |
| Relative Humidity | 0 … 95 % non-condensing |
| Mechanical parameters | |
| Degree of protection | IP20 |
| Connection | DB-9 connector, 2-pin polarity-insensitive test clips |
| Material | Polycarbonate |
| Dimensions | 49 mm x 33 mm x 15 mm |
| Height | 15 mm |
| Width | 33 mm |
| Length | 49 mm |
| Cable length | 1.8 m two-core cable, terminated with 2 test clips |
| General information | |
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals and manuals within the applicable scope. For related information, see www.pepperl-fuchs.com. |
- Compatible with Windows® 7, 10 and 11
- HART-compliant, communicates with any HART field device and performs error-free slave testing
- Easy to install
- Powered by the RS-232 port, no external power supply required for the modem
- Compact, rugged polycarbonate housing for industrial-grade reliability
- No polarity requirement for test clips
- Transformer isolated, can be connected across the load resistor or field device
Petrochemical Plant
HART field instrument commissioning and configuration communication
Power Energy System
DCS system HART multiplexer access
Process Automation
HART signal filtering and tapping between control room and field instruments
Documents not uploaded. Please fill in the information row by row in the 'Product Details Field' panel under 'File Name | Download Address | File Size'.
Need selection advice or bulk quotation?
Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.
- Phone consultation +86-21-66020232