IPAQ C310 RTD Temperature Transmitter
High-precision isolated temperature transmitter supporting RTD and resistance inputs, with NFC / Bluetooth wireless configuration and sensor and system error correction.
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
The IPAQ C310 RTD is an isolated temperature transmitter for resistance thermometer (RTD) sensor measurement. In addition to Pt10…Pt1000, it is also compatible with Ni100, Ni120, Ni1000 and resistance inputs. The rugged mechanical design and high-quality components ensure excellent performance and accuracy even under harsh conditions.
The IPAQ C310 RTD supports NFC (Near Field Communication) and Bluetooth® communication for remote transmitter configuration and monitoring; it can also be configured via PC using ConSoft software.
| Parameter Name | Technical Specifications |
|---|---|
| Basic Parameters | |
| Product Type | Integrated Head Assembly Type |
| Measurement Channels | Single Channel |
| Input | |
| Input Signal | Resistance thermometer (RTD), resistance |
| RTD Input | Pt100, Pt10…Pt1000, Ni100, Ni120, Ni1000 |
| Sensor Wiring | 2-Wire, 3-Wire, 4-Wire Wiring |
| Output and Communication | |
| Output Signal | 4-20 mA |
| Analogue output | Fixed current output for up to 15 minutes |
| Configuration Mode | ConSoft or INOR Connect |
| Wireless communication | NFC and Bluetooth® |
| Power Supply and Isolation | |
| Electrical Isolation | 1500 VAC for 1 minute |
| Power Supply | 8…36 VDC |
| Accuracy and Environment | |
| Typical Accuracy | Maximum ±0.1 °C or ±0.1% of Range |
| Long-term accuracy | Maximum drift ±0.02% of span/year |
| Vibration Resistance | IEC 60068-2-6, 10 g |
| Operating hour counter | Cumulative operating hours counter |
- High accuracy and excellent long-term stability
- Galvanic isolation between input and output
- Accepts RTD and resistance (Ω) inputs
- Sensor error and system (sensor + transmitter) error correction for higher overall accuracy
- Low temperature drift design
- Configurable via PC, NFC or Bluetooth®, no external power supply required
- Operating timer, records cumulative operating hours
- Rugged design, tested to 10 g vibration
- High security: password protection, traceable change log
Intrinsically safe temperature measurement in petrochemical plants
Isolated design with RTD input for applications with earth loops and interference voltages, suppressing measurement errors.
Temperature monitoring in heating networks
For temperature acquisition on steam and hot water pipelines; system error correction improves measurement accuracy across the entire loop.
Device status and calibration management
The runtime counter records cumulative operating time, providing a data basis for periodic calibration and verification.
Documents not uploaded. Please fill in the information row by row in the 'Product Details Field' panel under 'File Name | Download Address | File Size'.
Need selection advice or bulk quotation?
Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.
- Phone consultation +86-21-66020232
- Email inquiry web@qishan-sh.com