IPAQ C530 HART Temperature Transmitter (Wireless Type)

Product Model IPAQ C530

Product Brand

Product Category Temperature Instruments / Temperature Transmitters

HART® 7-compatible universal two-wire temperature transmitter with NFC® and Bluetooth® wireless configuration and extended diagnostic information.

Inquire Now
  • Original Factory Genuine, Tenfold Compensation for Counterfeits
  • Full Machine Warranty, Lifetime Maintenance
  • In Stock, Shipped on the Same Day

The IPAQ C530 is a modern HART® temperature transmitter that meets the highest standards of accuracy and reliability. As a universal transmitter, it is compatible with RTD, thermocouple, voltage and potentiometer sensors, offering high flexibility and reducing the number of product variants installed on site.

The IPAQ C530 is fully compatible with the HART® 7 protocol and provides extended diagnostic information (such as device faults, sensor and wiring status), delivering reliable measurement and excellent accuracy.

The IPAQ C530 supports NFC® (near-field communication) and Bluetooth® communication, enabling remote transmitter configuration and monitoring.

IPAQ C530 HART Temperature Transmitter (Wireless) Technical Specifications
Parameter Name Technical Specifications
Basic Parameters
Product Type Integrated Head Assembly Type
Transmitter Type Digital
Measurement Channels Single Channel
Input
Input Signal Resistance thermometer (RTD), thermocouple (TC), mV, resistance
RTD Input Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
Thermocouple Input Types B, C, D, E, J, K, N, R, S, T
Sensor Wiring 2-Wire, 3-Wire, 4-Wire Wiring
Minimum span adjustment 10 °C (18 °F), or sensor-dependent
Zero adjustment Any value within the range
Output and Communication
Output Signal 4-20 mA, HART protocol
HART® compatibility Fully compatible with HART® 7 protocol and backward compatible with HART® 6 and HART® 5
Configuration Mode ConSoft, INOR Connect, or EDD, DTM / FDT systems
Wireless connection NFC® and Bluetooth®
Analogue output Fixed current output for up to 15 minutes
Sensor fault response NAMUR NE43 standard
Error compensation Sensor error and system error correction
Power Supply and Isolation
Electrical Isolation 1500 VAC
Power Supply IPAQ-C530: 8.5…36 VDC IPAQ-C530X: 8.5…30 VDC
Accuracy and Environment
Typical Accuracy Max. ±0.08 K or ±0.08% of span
Long-term accuracy Maximum drift ±0.02% of span/year
Vibration Resistance IEC 60068-2-6, 10 g
Relative Humidity 0...98% RH (No Condensation)
Ambient Temperature -40…+85 °C (-40…+185 °F)
Operating hour counter Cumulative operating hours counter
Adjustable filter level 0.17…90 s (default 0.9 s) (3-wire RTD)
Certification and Compliance
Certification ATEX, IECEx, cFMus
Electromagnetic Compatibility (EMC) EN 61326-1 and EN 61326-2-3
  • Universal input: compatible with RTD, thermocouple, voltage (mV) and potentiometer sensors
  • Fully compatible with HART® 7 protocol and backward compatible with HART® 6 and HART® 5
  • Provides extended diagnostic information (device faults, sensor and wiring status)
  • Supports NFC® and Bluetooth® wireless configuration and monitoring
  • Isolated input/output design
  • ATEX, IECEx, FM certified versions available

Smart factory HART loop

Connects to HART communicators and asset management systems to read device diagnostics in real time, enabling predictive maintenance.

Remote configuration in hazardous areas

Configuration and monitoring via NFC and Bluetooth from the safe area, reducing the need to enter hazardous areas.

Multi-parameter process measurement points

Universal input covers RTD, thermocouple, mV and potentiometer, meeting the measurement requirements of different measurement points in the same plant.

Documents not uploaded. Please fill in the information row by row in the 'Product Details Field' panel under 'File Name | Download Address | File Size'.

Need selection advice or bulk quotation?

Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Inquire about the product

IPAQ C530 · IPAQ C530 HART 温度变送器(无线型)

Please enter the requirement description (at least 10 characters)

Online customer service
Online customer service Scan or click to contact directly
Contacts
Miss Chen(Safety barriers, isolators, surge protectors)
陈小姐 个人微信二维码

Scan WeChat QR code to add personal WeChat

QQ:2501529964

Phone:17717626508

Email:chenjing@qishan-sh.com

Miss Lu(Field Instruments, Valve Accessories, Terminal Blocks)
卢小姐 个人微信二维码

Scan WeChat QR code to add personal WeChat

QQ:1695457483

Phone:13636420802

Email:lhm@qishan-sh.com

Mr. Ye(Technical Support, After-Sales Service)

QQ:97010638

Phone:15800474322

Email:web@qishan-sh.com

Online Message

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Please enter the requirement description (at least 10 characters)