IPAQ R460 Four-wire Signal Transmitter

Product Model IPAQ R460

Product Brand

Product Category Temperature Instruments / Temperature Transmitters

Programmable four-wire (independent power supply) isolated transmitter, supporting Pt, Ni, KTY, thermocouple, potentiometer, resistance, and mV input, which can be configured via DIP switch or INOR-Set software.

Inquire Now
  • Original Factory Genuine, Tenfold Compensation for Counterfeits
  • Full Machine Warranty, Lifetime Maintenance
  • In Stock, Shipped on the Same Day

The IPAQ R460 is a programmable four-wire (independent power supply) transmitter that can convert Pt, Ni, KTY, thermocouple signals, as well as potentiometer, resistance, and mV signals into isolated standard signal outputs.

The IPAQ R460 can be configured via DIP switch or INOR-Set software. When using INOR-Set, configuration can be completed on a PC, and data can be recorded and archived; no additional power supply is required during PC configuration.

The debug (commissioning) function on the front panel, which can be opened, generates a reference signal at the output end, making it easy to test and adjust subsequent signal channels. Power can be supplied by terminal blocks or In-Rail-Bus connectors, and the front panel LED indicates the supply voltage and fault status.

IPAQ R460 四线制信号变送器 技术参数
Parameter Name Technical Specifications
Basic Parameters
Product Type Rack-mounting Type
Transmitter Type Digital
Measurement Channels Single Channel
Structural Design 6.2 mm (0.244″) side-by-side housing, protection class IP20, mounted on a 35 mm top hat rail that complies with EN 60715.
Weight Approx. 70 g
Input
Input Signal Resistance Thermometers, Thermocouples, mV, Resistance, and KTY
RTD Input Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni500, Ni1000
Thermocouple Input Types B, E, J, K, L, N, R, S, T, U, W5Re_W26Re, W3Re_W25Re
RTD Measurement Range Pt 100, Pt 200, Pt 500, Pt 1000: -200… +850 °C Ni 100: -60… +250 °C Ni 200, Ni 500, Ni 1000: -50… 180 °C
Thermocouple Measurement Range Type B: +250...+1820 °C, Type C (W5Re_W26Re): 0...+2315 °C, Type D (W3Re_W25Re): 0...+2315 °C, Type E: +270...+1000 °C, Type J: +210...+1200 °C, Type K: +200...+900 °C, Type L: +200...+900 °C, Type N: +270...+1300 °C, Type R: -50...+1768 °C, Type S: -50...+1768 °C, Type T: -270...+400 °C, Type U: +200...+600 °C
Sensor Wiring 2-wire, 3-wire, 4-wire wiring
Output and Communication
Output Signal 0...20 mA, 4...20 mA, 0...10 mA, 2...10 mA, 0...5 V, 0...10 V, 1...5 V, 2...10 V
Configuration Mode DIP switch or INOR-Set software
Power Supply and Isolation
Electrical Isolation 3 kV AC, 50 Hz, for 1 minute
Power Supply 24 V DC voltage range 9.6...31.2 VDC, power consumption approx. 0.8 W
Accuracy and Environment
Typical Accuracy Maximum ±0.05 K or ±0.05% measurement range
Ambient Temperature Operating temperature: -25...+70 °C (-13...+158 °F), Storage and transport temperature: -40...+85 °C (-40...+185 °F)
Certification and Compliance
Electromagnetic Compatibility (EMC) EN 61326-1
  • Configurable via DIP switch or INOR-Set software
  • Switchable operational (debugging) function for quick startup
  • 3-port isolation: prevents ground issues and interference voltage from causing measurement errors
  • Extremely narrow design: 6.2 mm parallel housing, top cap rail installation is simple and space-saving
  • Optional In-Rail-Bus connector for quick installation and lower cost
  • Safety isolation in accordance with EN 61140, protecting maintenance personnel and downstream equipment from abnormal high-voltage hazards
  • Supports Pt, Ni, KTY, thermocouples, potentiometers, resistors, and mV inputs

Signal Conversion and Isolation

Converts potentiometers, resistors, mV, etc., to isolated standard signals, eliminating ground loop and interference intrusion.

Equipment Sets and Integration

Quickly powered via In-Rail-Bus connectors, suitable for bulk cabinet and equipment integration delivery.

On-site debugging and verification

The commissioning function generates reference signals at the output end, facilitating rapid verification of subsequent signal channels.

Documents not uploaded. Please fill in the information row by row in the 'Product Details Field' panel under 'File Name | Download Address | File Size'.

Need selection advice or bulk quotation?

Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Inquire about the product

IPAQ R460 · IPAQ R460 four-wire signal transmitter

Please enter the requirement description (at least 10 characters)

Online customer service
Online customer service Scan or click to contact directly
Contacts
Miss Chen(Safety barriers, isolators, surge protectors)
陈小姐 个人微信二维码

Scan WeChat QR code to add personal WeChat

QQ:2501529964

Phone:17717626508

Email:chenjing@qishan-sh.com

Miss Lu(Field Instruments, Valve Accessories, Terminal Blocks)
卢小姐 个人微信二维码

Scan WeChat QR code to add personal WeChat

QQ:1695457483

Phone:13636420802

Email:lhm@qishan-sh.com

Mr. Ye(Technical Support, After-Sales Service)

QQ:97010638

Phone:15800474322

Email:web@qishan-sh.com

Online Message

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Please enter the requirement description (at least 10 characters)