IsoPAQ-12L Dual-Channel Loop-Powered Isolator
The IsoPAQ-12L is a dual-channel loop-powered isolator for electrical isolation of 0(4)–20 mA signals, preventing measurement errors caused by potential differences or earth loops in instrument installations.
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
The IsoPAQ-12L is a dual-channel loop-powered isolator for electrical isolation of 0(4)–20 mA signals, preventing measurement errors caused by potential differences or earth loops in instrument installations.
The IsoPAQ-12L combines high-density mounting with excellent cost-effectiveness.
The isolator requires no external power supply, reducing installation costs compared with isolated transmitters.
High reliability ensures safe system operation and reduces maintenance costs.
Ordering information
| Model / Specification | Order number |
|---|---|
| IsoPAQ-11L 1-channel, 0(4)-20 mA | 70ISL11001 |
| IsoPAQ-12L 2-channel, 0(4)-20 mA | 70ISL12001 |
| Parameter Name | Technical Specifications |
|---|---|
| Technical specifications | |
| Input type | Passive |
| Number of Channels | Dual Channel |
| Input Signal | 0(4)…20 mA |
| Output Signal | 0(4)…20 mA |
| Typical Accuracy | 0.1 % FS |
| Isolation voltage | 1.5 kV, 50 Hz |
| Power Supply | None |
| Response time | < 5 ms |
| Ambient Temperature | 20…+70 °C |
| Pluggable screw terminals | Yes |
| Shell Width | 12.5 mm |
| Mounting depth | 104 mm |
- The IsoPAQ-12L is a dual-channel loop-powered isolator for electrical isolation of 0(4)–20 mA signals, preventing measurement errors caused by potential differences or earth loops in instrument installations.
- The IsoPAQ-12L combines high-density mounting with excellent cost-effectiveness.
- The isolator requires no external power supply, reducing installation costs compared with isolated transmitters.
Process loop signal isolation
Interfaces two-wire transmitters with the control system in DCS/PLC analogue loops, eliminating measurement errors caused by ground potential differences and earth loops.
Hazardous area signal conditioning
In refining and petrochemical units, 4–20 mA signals are isolated and distributed to the control system and safety interlock loops, ensuring a reliable signal chain.
Need selection advice or bulk quotation?
Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.
- Phone consultation +86-21-66020232
- Email inquiry web@qishan-sh.com