IsoPAQ-661 Bipolar Isolated Amplifier
The IsoPAQ-661 bipolar isolated amplifier is used for the isolation and conversion of industrial standard bipolar and unipolar signals.
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
The IsoPAQ-661 bipolar isolated amplifier is used for the isolation and conversion of industrial standard bipolar and unipolar signals.
The input and output ranges of the IsoPAQ-661 can be conveniently set via DIP switches. Thanks to the calibrated range selection, no further adjustment is required.
The measuring range can be switchably compensated via the zero/span potentiometers on the front panel. The cut-off frequency can also be adjusted to the measurement task via DIP switches.
Auxiliary power can be supplied via terminals or the optional In-Rail-Bus rail bus connector. A green LED on the front panel monitors power status.
| Parameter Name | Technical Specifications |
|---|---|
| Technical specifications | |
| Input current (calibrated, switchable) | ±20 mA, 0… 20 mA, 4… 20 mA ±10 mA, 0… 10 mA, 2… 10 mA |
| Input voltage (calibrated, switchable) | ±10 V, 0… 10 V, 2 … 10 V ±5 V, 0… 5 V, 1 … 5 V |
| Input Impedance | Current: ≤ 25 Ω Voltage: ≥ 1 MΩ |
| Overload | Current: < 50 mA Voltage: < 30 V |
| Output current (calibrated, switchable) | ±20 mA, 0… 20 mA, 4… 20 mA ±10 mA, 0… 10 mA, 2… 10 mA |
| Output voltage (calibrated, switchable) | ±10 V, 0… 10 V, 2 … 10 V ±5 V, 0… 5 V, 1 … 5 V |
| Load | Current: ≤ 12 V (600 Ω at 20 mA) Voltage: ≤ 5 mA (2 kΩ at 10 V) |
| Linear transmission range | Unipolar: -1… +110 % Bipolar: -110… +110 % |
| Residual ripple | < 10 mV rms |
| Transmission error | < 0.1 % full scale |
| Temperature coefficient | < 100 ppm/K |
| Zero/span compensation | 5% of measuring range |
| Cut-off frequency (-3 dB) | Current: 8 kHz Voltage: 100 Hz |
| Response time T99 | 100 µs / 7 ms |
| Test voltage | 3 kV AC, 50 Hz, 1 min. Input against output against power supply |
| Operating voltage (basic insulation) | 600 V AC/DC for overvoltage category II and pollution degree 2 acc. to EN 61010-1 |
| Protection against electric shock | Protective separation according to EN 61140 by reinforced insulation in accordance with EN 61010-1 up to 300 V AC/DC for overvoltage category II and pollution degree 2 between all circuits. |
| Ambient Temperature | Operation – 25 °C to + 70 °C (– 13 to + 158 °F) Transport and storage – 40 °C to + 85 °C (– 40 to + 185 °F) |
| Power Supply | 24 V DC voltage range 16.8 V … 31.2 V DC, approx. 0.8 W |
| Electromagnetic compatibility | EN 61326-1 |
| Structure type | 62 x 96.5 x 107 mm, protection class IP 20, mounting on 35 mm DIN rail acc. to EN 60715 |
| Weight | Approx. 70 g |
- The IsoPAQ-661 bipolar isolated amplifier is used for the isolation and conversion of industrial standard bipolar and unipolar signals.
- The input and output ranges of the IsoPAQ-661 can be conveniently set via DIP switches. Thanks to the calibrated range selection, no further adjustment is required.
- The measuring range can be switchably compensated via the zero/span potentiometers on the front panel. The cut-off frequency can also be adjusted to the measurement task via DIP switches.
Process loop signal isolation
Interfaces two-wire transmitters with the control system in DCS/PLC analogue loops, eliminating measurement errors caused by ground potential differences and earth loops.
Hazardous area signal conditioning
In refining and petrochemical units, 4–20 mA signals are isolated and distributed to the control system and safety interlock loops, ensuring a reliable signal chain.
Need selection advice or bulk quotation?
Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.
- Phone consultation +86-21-66020232
- Email inquiry web@qishan-sh.com