M-LB-4.275TNS.D 4-channel surge protection isolator
Surge protection for 4 power supply lines, Type 2 (in accordance with EN 61643-11), for TN-S systems (230 V AC/400 V AC), pre-wired unit.
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
Pepperl+Fuchs M-LB-4.275TNS.D 4-channel surge protection isolator, surge protection for 4 power supply lines, Type 2 (in accordance with EN 61643-11), for TN-S systems (230 V AC/400 V AC), pre-wired unit, operating status and fault indication per protected line.
For lightning and switching overvoltage protection of signal lines, power lines and fieldbus lines between hazardous areas and safe areas, DIN rail or field enclosure mounting, directly connected in series in instrument loops, DCS/PLC I/O and bus trunk/spur lines.
| Parameter Name | Technical Specifications |
|---|---|
| General specifications | |
| Device type | Type 2 in accordance with EN 61643-11, Class II in accordance with IEC 61643-11 |
| Number of protected power supply lines | 4 |
| Suitable components | Protection module M-LB-1.275.M |
| Electrical Data | |
| Rated Voltage | 230 V AC, 50 … 60 Hz, 400 V AC, 50 … 60 Hz |
| Maximum continuous operating voltage | 275 V AC, 50 … 60 Hz |
| Temporary overvoltage | 335 V, 5 s (TOV withstand) |
| Nominal discharge current (8/20 µs) | 20 kA |
| Maximum surge current (8/20 µs) | 40 kA |
| Voltage protection level | Max. 1.25 kV, max. 1 kV at 5 kA |
| Response time | Max. 25 ns |
| Short-circuit withstand | 50 kA eff |
| Overcurrent protection | Max. 125 A gG, supply side |
| Fault indication output | |
| Connection | Terminals 11, 12, 14 |
| Output | Passive changeover contact |
| Switching capacity | AC: 250 V, 0.5 A, DC: 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A; 24 V/0.5 A |
| Indication/setting | |
| Display elements | Status display / operating status (green) / fault indication (red) |
| Directive conformity | |
| Directive 2014/35/EU | EN 61643-11:2012 |
| Conformity | |
| Degree of protection | IEC 60529 |
| Shock resistance | EN 60068-2 |
| Vibration Resistance | EN 60068-2 |
| Ambient Conditions | |
| Ambient Temperature | −40 … 80 °C (−40 … 176 °F) |
| Relative Humidity | 5 … 95 % |
| Mechanical parameters | |
| Degree of protection | IP20 |
| Core cross-section | - Min. 1.5 mm2 solid/flexible, - Max. 35 mm2 stranded/25 mm2 flexible, - Max. 1.5 mm2 solid/flexible (for remote signalling contact) |
| Housing | thermoplastic, colour grey, UL 94 V-0 |
| Weight | Approx. 480 g |
| Dimensions | 72 x 90 x 72 mm (2.8 x 3.6 x 2.8 inch) (W × H × D), 4 TE (in accordance with DIN 43880) |
| Installation Method | Mounts on 35 mm DIN mounting rail in accordance with EN 60715:2001 |
| General information | |
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals and manuals within the applicable scope. For related information, see www.pepperl-fuchs.com. |
- Surge protection for 4 supply lines
- Type 2 (in accordance with EN 61643-11)
- For TN-S systems (230 V AC/400 V AC)
- Pre-wired unit
- Operating status and fault indication per protected line
- Fault indication output
- DIN rail mountable
Petrochemical Plant
Lightning and overvoltage protection for instrument signal circuits
Power Energy System
Surge protection for power and signal lines
Process Automation
Surge protection for fieldbus trunk and spur lines
Documents not uploaded. Please fill in the information row by row in the 'Product Details Field' panel under 'File Name | Download Address | File Size'.
Need selection advice or bulk quotation?
Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.
- Phone consultation +86-21-66020232
- Email inquiry web@qishan-sh.com