MinIPAQ C230 Integrated Temperature Transmitter
Universal non-isolated two-wire integrated head-mounted transmitter, supporting RTD, thermocouple, resistance and mV input, configurable via NFC / Bluetooth or PC.
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
The MinIPAQ C230 is a universal, non-isolated, two-wire integrated head-mounted transmitter for temperature measurement and other measurement applications.
Its robust design and high-quality components ensure good performance and accuracy even under harsh conditions. The transmitter accepts a wide range of resistance thermometer (RTD), thermocouple (TC) and linear resistance and mV signal inputs.
The transmitter is easily configured via the INOR Connect mobile app — either wirelessly via NFC or via a connected Bluetooth® modem; configuration can also be completed using ConSoft software on a PC.
| Parameter Name | Technical Specifications |
|---|---|
| Basic Parameters | |
| Product Type | Universal digital integrated head-mounted two-wire signal transmitter |
| Installation Method | Mounts in terminal heads compliant with DIN EN 50446 type B and above |
| Input | |
| Input Signal | Resistance thermometer (RTD), thermocouple (TC), mV and Ω |
| Resistance input (2/3/4-wire) | Pt10…Pt1000, Ni100, Ni120, Ni1000 |
| Thermocouple Input | Types B, C, D, E, J, K, N, R, S, T |
| mV input | -10…+1000 mV |
| Resistance input (2/3/4-wire) | 0…4000 Ω (0…2000 Ω in 2-wire connection) |
| Output and Communication | |
| Output Signal | 4-20 mA (RTD, TC temperature linear), two-wire loop-powered |
| Output signal and sensor fault | Compliant with NAMUR NE43 |
| Configuration Mode | ConSoft Windows software or INOR Connect mobile app |
| Wireless configuration | NFC and Bluetooth® |
| Power Supply and Isolation | |
| Electrical Isolation | No isolation, non-isolated |
| Supply voltage (with polarity protection) | 8…36 VDC |
| Accuracy and Environment | |
| Typical accuracy (RTD) | Max. ±0.15 K or ±0.15% of span |
| Typical accuracy (type J, K thermocouples) | Max. ±0.5 K or ±0.25% of span, ±1 K (cold junction compensation) |
| Long-term drift | Max. ±0.05% of span/year |
| Vibration Resistance | IEC 60068-2-6, 10 g |
| Certification and Compliance | |
| Electromagnetic Compatibility (EMC) | Compliant with EN 61326-1 and EN 61326-2-3 |
| RoHS | Compliant with RoHS directive |
- Resistance thermometer (RTD) and resistance input, supporting 2-wire, 3-wire and 4-wire connection
- Thermocouple (TC) and mV signal input
- Mountable in DIN type B and larger terminal heads
- Configurable via PC, NFC or Bluetooth®, no external power supply required
- Sensor error correction and system error (sensor + transmitter) correction for higher overall accuracy
- Operating timer, records cumulative operating hours
- Rugged design, tested to 10 g vibration
- High security: parameter changes are password-protected
- Remote configuration and monitoring via connected Bluetooth® modem
General industrial temperature measurement
One model covers both RTD and thermocouple, suitable for retrofit and new-build projects with diverse measurement point types.
Temperature measurement on pumps, valves and pipework
Integrated head mounting, installed directly in the terminal head, ideal for space-constrained field installations.
Remote configuration and monitoring
Remote configuration and monitoring via Bluetooth modem, reducing on-site climbing and inspection effort.
Documents not uploaded. Please fill in the information row by row in the 'Product Details Field' panel under 'File Name | Download Address | File Size'.
Need selection advice or bulk quotation?
Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.
- Phone consultation +86-21-66020232
- Email inquiry web@qishan-sh.com