SC3035 Potentiometer Transmitter (One In, One Out)

Product Model SC3035

Product Brand

Product Category Industrial Safety and Signal Conditioning Module / Signal Isolator

Application Industry Petrochemical, process automation

Potentiometer transmitter: 3-wire 0-10kΩ potentiometer input, isolated conversion to 4-20mA and other standard signals, zero and span configurable via PC/programmer.

Inquire Now
  • Original Factory Genuine, Tenfold Compensation for Counterfeits
  • Full Machine Warranty, Lifetime Maintenance
  • In Stock, Shipped on the Same Day

Potentiometer transmitter, 3-wire potentiometer signal input, isolated conversion to current/voltage signal. This product requires independent power supply, with three-port isolation between input, output and power supply, online fault self-diagnostics, and configuration of potentiometer zero and span, output signal type, and output mode on signal fault via PC or handheld programmer.

Note:Three-port isolation between input, output and power supply. 24V DC independent power supply; input side connected in 3-wire potentiometer configuration (the three potentiometer terminals are connected to the module input terminals respectively to eliminate the effect of line resistance); output side provides 4-20mA (active/passive) or voltage signal to DCS/PLC according to the selected model. Module indicators: green power indicator, red fault signal. All terminals are hot-swappable. Refer to the silkscreen on the module side for specific terminal numbers.

Ordering information:

  • The output signal type is determined by the ordering code; default is 4-20mA; for non-standard signals, select code 7 and specify the signal specification when ordering.
  • Power supply is 24VDC by default; select code A for 220VAC power supply.
SC3035 Potentiometer Transmitter (One In, One Out) Technical Parameters
Parameter Name Technical Specifications
Power supply and power consumption
Power Supply 18V DC~60V DC power reverse protection
Full-load power consumption 0.8W (24V, single channel full load output); 1.2W (24V, dual channel full load output)
Input characteristics
Input Signal 3-wire potentiometer 0kΩ~10kΩ
Output and load
Output Signal Current: active/passive 0/4~20mA, 0~10mA; Voltage: 0/1~5V, 0~10V
Load requirements 0/4~20mA: RL≤550Ω; 0~10mA: RL≤1.1kΩ; 0/1~5V: RL≥1MΩ; 0~10V: RL≥2MΩ
Permissible load Passive: RL<[(U-3)/0.02]Ω; U is the loop voltage
Accuracy and response
Conversion accuracy 0.1%F.S
Temperature drift 30ppm/℃
Response time ≤500ms
Isolation and electromagnetic compatibility
Electromagnetic compatibility IEC 61326-3-1
Dielectric strength ≥1500V AC (between input/output/power supply)
Insulation resistance ≥100MΩ (between input/output/power supply)
Environmental and Mechanical
IP Protection IP20
Operating Temperature -20℃~+60℃
Storage Temperature -40℃~+80℃
Dimensions 12.8mm×110mm×117mm (W×H×D)
Product Selection Code
Output Signal (Code 1) Defaults to standard 4-20mA output
Output Signal (Code 2) 1~5V
Output Signal (Code 3) 0~10mA
Output signal (code 4) 0~5V
Output signal (code 5) 0~10V
Output signal (code 6) 0~20mA
Output Signal (Code 7) Other customised signals
Power supply method (code default) Default 24VDC power supply
Power supply (code A) 220VAC power supply
  • 3-wire potentiometer 0-10kΩ input, eliminating the effect of line resistance
  • Output 0/4–20 mA, 0–10 mA, 0/1–5 V, 0–10 V, as determined by the model code
  • Potentiometer zero, span and fault output mode configurable via PC or handheld programmer
  • Online fault self-diagnostics, broken wire output 0V/mA
  • Conversion accuracy 0.1%F.S., temperature drift 30ppm/°C
  • Power supply 18V DC~60V DC, optional 220VAC

Valve actuator position feedback transmission

Valve actuator position feedback (0-10kΩ potentiometer) transmitted as standard 4-20mA signal to DCS/PLC

Fine chemical dosing valve position feedback

Potentiometer valve position feedback transmission in dosing systems, multiple systems sharing the same process signal

Need selection advice or bulk quotation?

Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Inquire about the product

SC3035 · SC3035 Potentiometer Transmitter (One In, One Out)

Please enter the requirement description (at least 10 characters)

Online customer service
Online customer service Scan or click to contact directly
Contacts
Miss Chen(Safety barriers, isolators, surge protectors)
陈小姐 个人微信二维码

Scan WeChat QR code to add personal WeChat

QQ:2501529964

Phone:17717626508

Email:chenjing@qishan-sh.com

Miss Lu(Field Instruments, Valve Accessories, Terminal Blocks)
卢小姐 个人微信二维码

Scan WeChat QR code to add personal WeChat

QQ:1695457483

Phone:13636420802

Email:lhm@qishan-sh.com

Mr. Ye(Technical Support, After-Sales Service)

QQ:97010638

Phone:15800474322

Email:web@qishan-sh.com

Online Message

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Please enter the requirement description (at least 10 characters)