SC3042 Analog Input Isolator (one input and one output, HART compliant)

Product Model SC3042

Product Brand

Product Category Industrial Safety and Signal Conditioning Module / Signal Isolator

Application Industry Petrochemical, process automation

Current input isolator: provides isolated power supply for 2/3-wire transmitters and detects 4-20mA signals, isolated transmission output, supports bidirectional HART digital signal pass-through.

Inquire Now
  • Original Factory Genuine, Tenfold Compensation for Counterfeits
  • Full Machine Warranty, Lifetime Maintenance
  • In Stock, Shipped on the Same Day

Current input isolator, provides 1 channel of isolated power supply for 2-wire and 3-wire transmitters, simultaneously detects the current signal output by the transmitter, and outputs it after isolated transmission, while supporting bidirectional HART digital signal transmission. It features fast response, low temperature drift and high accuracy. This product requires an independent power supply, with three-terminal isolation of input, output and power supply.

Note:Three-terminal isolation of input, output and power supply. 24V DC independent power supply; the input side provides 1 channel of isolated power supply for 2-wire/3-wire transmitters (open-circuit voltage ≤26V, output voltage at 20mA ≥22V) and detects the transmitter current signal; the output side provides 0/4~20mA (RL≤550Ω) to the DCS/PLC AI channel; bidirectional HART digital signal transmission, with pass-through on both input and output sides. Module indicators: green power indicator, red fault signal. All terminals are hot-swappable. The specific terminal numbers are subject to the silkscreen on the side of the module.

Ordering information:

  • This product requires an independent power supply (18V DC~60V DC).
  • When ordering, confirm whether the connected transmitter is 2-wire or 3-wire and whether the power supply capability is sufficient (open-circuit ≤26V).
SC3042 Analogue Input Isolator (one in, one out, HART pass-through) Technical Specifications
Parameter Name Technical Specifications
Power supply and power consumption
Power Supply 18V DC–60V DC
Power consumption ≤1.3W (24V, general-purpose one in, one out at full load output)
Input characteristics
Input Signal 0/4–20mA
Input Impedance 50Ω
Distribution voltage Open-circuit voltage ≤26V, output voltage ≥22V at 20mA
Output and load
Output Signal 0/4–20mA
Permissible load 0/4–20mA: RL≤550Ω
Accuracy and response
Conversion accuracy 0.1%F.S.
Temperature drift 30ppm/℃
Response time ≤2ms
Isolation and electromagnetic compatibility
Electromagnetic compatibility IEC 61326-3-1
Dielectric strength ≥1500V AC (between input/output/power supply)
Insulation resistance ≥100MΩ (between input/output/power supply)
Environmental and Mechanical
IP Protection IP20
Operating Temperature -20℃~+60℃
Storage Temperature -40℃~+80℃
Dimensions 12.8mm×110mm×117mm (W×H×D)
  • Provides 1 channel of isolated power supply for 2-wire and 3-wire transmitters (open-circuit voltage ≤26V, ≥22V at 20mA)
  • 0/4~20mA isolated transmission output, response time ≤2ms
  • Supports bidirectional HART digital signal transmission for remote configuration and diagnostics by the host system
  • Three-port isolation of input, output and power supply
  • Conversion accuracy 0.1%F.S., temperature drift 30ppm/°C
  • DIN rail mounting, hot-swappable terminals

Transmitter power supply and signal isolation

4-20mA signal of 2-wire/3-wire transmitters (pressure, level, flow) is isolated and transmitted to DCS/PLC, while HART digital signals are passed through for remote configuration and diagnostics

Signal isolation and distribution in petroleum tank farms

Signal isolation and distribution for level/pressure transmitters in tank farms; flow signal acquisition for oil and gas pipelines

Need selection advice or bulk quotation?

Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Inquire about the product

SC3042 · SC3042 模拟量输入隔离器(一进一出,HART通过型)

Please enter the requirement description (at least 10 characters)

Online customer service
Online customer service Scan or click to contact directly
Contacts
Miss Chen(Safety barriers, isolators, surge protectors)
陈小姐 个人微信二维码

Scan WeChat QR code to add personal WeChat

QQ:2501529964

Phone:17717626508

Email:chenjing@qishan-sh.com

Miss Lu(Field Instruments, Valve Accessories, Terminal Blocks)
卢小姐 个人微信二维码

Scan WeChat QR code to add personal WeChat

QQ:1695457483

Phone:13636420802

Email:lhm@qishan-sh.com

Mr. Ye(Technical Support, After-Sales Service)

QQ:97010638

Phone:15800474322

Email:web@qishan-sh.com

Online Message

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Please enter the requirement description (at least 10 characters)