SC3047 Analogue Input Isolator (Intelligent, One In One Out)

Product Model SC3047

Product Brand

Product Category Industrial Safety and Signal Conditioning Module / Signal Isolator

Application Industry Petrochemical, process automation

Intelligent signal isolation converter: DC current/voltage input is isolated and transmitted as current/voltage output; input and output types are determined by the selection code; online fault self-diagnostics.

Inquire Now
  • Original Factory Genuine, Tenfold Compensation for Counterfeits
  • Full Machine Warranty, Lifetime Maintenance
  • In Stock, Shipped on the Same Day

Signal isolation converter that isolates and transmits an input current or voltage signal into a current or voltage output. This product requires an independent power supply, with three-port isolation between input, output and power supply, and features online fault self-diagnostics.

Note:Three-port isolation between input, output and power supply. Independent 24V DC (or 220VAC) power supply; the input side connects to a DC current or DC voltage signal per the selection code; the output side outputs the corresponding current/voltage signal per the selection code. The module features online fault self-diagnostics; on input disconnection or short circuit, it outputs 0V/mA. Module indicators: green power indicator, red fault signal. All terminals are hot-swappable. Refer to the silkscreen on the module side for specific terminal numbers.

Ordering information:

  • When ordering, the input signal, output signal and power supply method must be specified per the selection code.
  • Factory example: 1-5V input, 4-20mA output, 220VAC power supply, model SC3047-2A.
SC3047 Analogue Input Isolator (Intelligent, One In One Out) Technical Specifications
Parameter Name Technical Specifications
Power supply and power consumption
Power Supply 18V DC~60V DC; 85V AC~265V AC
Power consumption ≤1.5W (24V, intelligent one in one out at full load output)
Input characteristics
Input Signal DC current, DC voltage
Input Impedance DC current: 60Ω; DC voltage: ≥1MΩ
Distribution voltage Open-circuit voltage ≤26V, output voltage ≥22V at 20mA
Output and load
Output Signal DC current: active/passive 0/4~20mA, 0~10mA; DC voltage: 0/1~5V, 0~10V
Permissible load 0/1~5V, 0~10V see load requirements; 0/4~20mA: RL≤500Ω, 0~10mA: RL≤1kΩ; 0/1~5V: RL≥20kΩ, 0~10V: RL≥20kΩ; passive: RL<[(U-3)/0.022]Ω; U is the loop voltage
Accuracy and response
Conversion accuracy 0.1%F.S.
Temperature drift 30ppm/℃
Response time ≤500ms
Isolation and electromagnetic compatibility
Electromagnetic compatibility IEC 61326-3-1
Dielectric strength ≥1500V AC (between input/output/power supply)
Insulation resistance ≥100MΩ (between input/output/power supply)
Environmental and Mechanical
IP Protection IP20
Operating Temperature -20℃~+60℃
Storage Temperature -40℃~+80℃
Dimensions 12.8mm×110mm×117mm (W×H×D)
Product Selection Code
Input signal (code 1) 4-20mA
Input signal (code 2) 1~5V
Input signal (code 3) 0~10mA
Input signal (code 4) 0~5V
Input signal (code 5) 0~10V
Input signal (code 6) 0~20mA
Input signal (code 7) Other customised signals
Output signal (code *) Same as input signal code
Power supply method (code default) Default 24VDC power supply
Power supply (code A) 220VAC power supply
  • DC current/voltage signal isolation conversion, input and output types flexibly determined by the selection code
  • Online fault self-diagnostics; outputs 0V/mA on input open-circuit or short-circuit
  • Optional 220VAC power supply (85V AC~265V AC)
  • Input impedance: DC current 60Ω, DC voltage ≥1MΩ
  • Conversion accuracy 0.1%F.S., temperature drift 30ppm/°C
  • DIN rail mounting, hot-swappable terminals

Standard signal isolation conversion and range adaptation

Isolation conversion and range adaptation of standard DC current/voltage signals; for applications requiring flexible configuration of input/output signal types via a PC programmer

Need selection advice or bulk quotation?

Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Inquire about the product

SC3047 · SC3047 模拟量输入隔离器(智能型,一进一出)

Please enter the requirement description (at least 10 characters)

Online customer service
Online customer service Scan or click to contact directly
Contacts
Miss Chen(Safety barriers, isolators, surge protectors)
陈小姐 个人微信二维码

Scan WeChat QR code to add personal WeChat

QQ:2501529964

Phone:17717626508

Email:chenjing@qishan-sh.com

Miss Lu(Field Instruments, Valve Accessories, Terminal Blocks)
卢小姐 个人微信二维码

Scan WeChat QR code to add personal WeChat

QQ:1695457483

Phone:13636420802

Email:lhm@qishan-sh.com

Mr. Ye(Technical Support, After-Sales Service)

QQ:97010638

Phone:15800474322

Email:web@qishan-sh.com

Online Message

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Please enter the requirement description (at least 10 characters)