SC3048 Analogue Input Isolator (Intelligent, One-In Two-Out)
Intelligent signal isolation converter, one-in two-out: one current/voltage signal is isolated and distributed to two outputs of different forms, as determined by the ordering code.
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
Same as SC3047, single-channel one-in two-out configuration; the signal types of the two outputs can be determined separately via the ordering code. Requires independent power supply; three-port isolation between input, output and power supply; with online fault self-diagnostics.
Note:Three-port isolation between input, output and power supply. Independent 24V DC (or 220VAC) power supply; the input side accepts DC current/voltage signals per the ordering code; the output side comprises Output 1 and Output 2, with signal types determined separately per the ordering code. Module indicators: green power indicator, red fault signal. All terminals are hot-swappable. Refer to the silkscreen on the module side for specific terminal numbers.
Ordering information:
- When ordering, the input signal, the two output signals and the power supply method must be specified per the ordering code.
- Factory example: 1-5V input, two 4-20mA outputs, 220VAC power supply, model SC3048-2A.
| Parameter Name | Technical Specifications |
|---|---|
| Power supply and power consumption | |
| Power Supply | 18V DC~60V DC; 85V AC~265V AC |
| Power consumption | ≤2.0W (24V, intelligent one-in two-out at full-load output) |
| Input characteristics | |
| Input Signal | DC current, DC voltage |
| Input Impedance | DC current: 60Ω; DC voltage: ≥1MΩ |
| Distribution voltage | Open-circuit voltage ≤26V, output voltage ≥22V at 20mA |
| Output and load | |
| Output Signal | DC current: active/passive 0/4~20mA, 0~10mA; DC voltage: 0/1~5V, 0~10V |
| Permissible load | 0/4~20mA: RL≤500Ω, 0~10mA: RL≤1kΩ; 0/1~5V: RL≥20kΩ, 0~10V: RL≥20kΩ; passive: RL<[(U-3)/0.022]Ω; U is loop voltage |
| Accuracy and response | |
| Conversion accuracy | 0.1%F.S. |
| Temperature drift | 30ppm/℃ |
| Response time | ≤500ms |
| Isolation and electromagnetic compatibility | |
| Electromagnetic compatibility | IEC 61326-3-1 |
| Dielectric strength | ≥1500V AC (between input/output/power supply) |
| Insulation resistance | ≥100MΩ (between input/output/power supply) |
| Environmental and Mechanical | |
| IP Protection | IP20 |
| Operating Temperature | -20℃~+60℃ |
| Storage Temperature | -40℃~+80℃ |
| Dimensions | 12.8mm×110mm×117mm (W×H×D) |
| Product Selection Code | |
| Input signal (code 1) | 4-20mA |
| Input signal (code 2) | 1~5V |
| Input signal (code 3) | 0~10mA |
| Input signal (code 4) | 0~5V |
| Input signal (code 5) | 0~10V |
| Input signal (code 6) | 0~20mA |
| Input signal (code 7) | Other customised signals |
| Output signal 1 (code *) | Same as input signal code |
| Output signal 2 (code *) | Same as input signal code |
| Power supply method (code default) | Default 24VDC power supply |
| Power supply (code A) | 220VAC power supply |
- One-in two-out; the signal types of the two outputs are determined separately by the ordering code
- One 4-20mA to DCS, one 0-10V to recorder
- Online fault self-diagnostics; outputs 0V/mA on input open-circuit or short-circuit
- Optional 220VAC power supply
- Conversion accuracy 0.1%F.S., temperature drift 30ppm/°C
- DIN rail mounting, hot-swappable terminals
One signal, two output forms
One current/voltage signal, after isolation, is distributed to two outputs of different forms (e.g. one 4-20mA to DCS, one 0-10V to recorder)
Need selection advice or bulk quotation?
Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.
- Phone consultation +86-21-66020232
- Email inquiry web@qishan-sh.com