HiDMux2700 Type 32-channel HART multiplexer

Product Model HiDMux2700

Product Brand

Product Category Industrial Safety and Signal Conditioning Modules / HART Interface Devices, Industrial Safety and Signal Conditioning Modules

Application Industry Power Energy, Petroleum Chemical Industry, Process Automation

32 channels, 24 V DC supply, HART field device inputs (protocol versions 5–7), RS-485 interface.

Inquire Now
  • Original Factory Genuine, Tenfold Compensation for Counterfeits
  • Full Machine Warranty, Lifetime Maintenance
  • In Stock, Shipped on the Same Day

Pepperl+Fuchs HiDMux2700 HART multiplexer, 32 channels, 24 V DC supply, HART field device inputs (protocol versions 5–7), RS-485 interface, up to SIL 3 (in accordance with IEC/EN 61508).

Part of the HART Interface Devices series, used for communication access, signal tapping and commissioning configuration between DCS/PLC control systems and HART field instruments, supporting HART protocol (including WirelessHART) multiplexing, loop conversion and filtering, and compatible with mainstream barriers and termination boards.

HiDMux2700 32-channel HART multiplexer technical data
Parameter Name Technical Specifications
Functional safety parameters
Safety Integrity Level (SIL) SIL 3
Power Supply
Connection SL1: 1a, 1b(-); 2a, 2b(+)
Rated Voltage 20.4 … 30 V DC via termination board
Rated current 28 mA at 24 V, RS-485, quiescent current
Power dissipation 0.7 W at 24 V
HART signal channel (non-intrinsically safe)
Number of Channels 32
Conformity HART field device input (protocol version 5–7)
Signal range 0.12 Vpp < signal < 1.5 Vpp
Leakage current < 3 µA at −20 … 85 °C (−4 … 185 °F)
Terminating resistor external 230 … 500 Ω standard (up to 1000 Ω possible)
Output voltage ≥ 400 mV ss (with the above terminating resistor)
Output resistance ≤100 Ω, capacitively coupled
DC isolation Dual capacitor per channel
Common-mode voltage up to 30 V
Input Impedance > 5 kΩ, according to HART specification
Input voltage range 0.12 … 1.5 V ss
Common-mode voltage Max. 30 V
Differential-mode clamping ± 5.2 V (transient or AC signal)
Common-mode clamping ± 10 V (transient or AC signal)
Carrier detection level signal > 0.12 Vpp, carrier detection activated, signal < 0.08 Vpp, carrier detection not activated
Transmit amplitude 200 Ω load, 0.43 Vpp < signal < 0.49 Vpp, 500 Ω load, 1.1 Vpp < signal < 1.2 Vpp
Device type DC isolated bus device
Impedance High impedance
Data link type HART primary and secondary
Field-side multidrop support Optional, consult factory
Interface
Transmission Rate 9600/19200/38400 MBit/s, selectable via switch
Address 1 … 31 (adjustable via DIP switch)
Type RS-485, differential pair and grounding
Topology Multidrop, master module/slave module connection
Electrical Isolation
Interface/power supply 500 Vrms
Interface/field channel 1000 Veff
Power supply/field channel 1000 Veff
Indication/setting
Display elements LEDs, LED PWR ON (power supply), one green LED, LED HART TX (HART transmission), one yellow LED, LED FAULT (lead fault), one red LED
Operating elements DIP switch on the side of the housing, for: slave module address, baud rate, test mode on/off
Configuration via DIP switch
Marking Reserved marking area on the front
Directive conformity
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Conformity
Electromagnetic compatibility NE 21:2012, see system description
Degree of protection IEC 60529:2001
Ambient Conditions
Ambient Temperature −20 … 60 °C (−4 … 140 °F)
Relative Humidity 5 … 95 %, non-condensing
Mechanical parameters
Degree of protection IP20
Weight approx. 140 g
Dimensions 18 x 114 x 130 mm (0.7 x 4.5 x 5.1 inch) (W × H × D)
Installation Method Located on the termination board
Hazardous area application data
Certificate CML 17 ATEX 3337X
Marking II 3G Ex ec IIC T4 Gc
Directive 2014/34/EU EN IEC 60079-0:2018+AC:2020, EN 60079-7:2015+A1:2018
International approvals
CSA certificate 1256050
Certification scope Class I, Division 2, Groups A, B, C, D and non-explosion hazardous area
IECEx certificate IECEx CML 17.0178X
IECEx marking Ex ec IIC T4 Gc
General information
Supplementary information Observe the certificates, declarations of conformity, instruction manuals and manuals within the applicable scope. For related information, see www.pepperl-fuchs.com.
  • 32 channels
  • 24 V DC supply
  • HART field device input (protocol version 5–7)
  • RS-485 interface
  • Up to SIL 3 (in accordance with IEC/EN 61508)

Petrochemical Plant

HART field instrument commissioning and configuration communication

Power Energy System

DCS system HART multiplexer access

Process Automation

HART signal filtering and tapping between control room and field instruments

Documents not uploaded. Please fill in the information row by row in the 'Product Details Field' panel under 'File Name | Download Address | File Size'.

Need selection advice or bulk quotation?

Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Inquire about the product

HiDMux2700 · HiDMux2700 32-channel HART multiplexer

Please enter the requirement description (at least 10 characters)

Online customer service
Online customer service Scan or click to contact directly
Contacts
Miss Chen(Safety barriers, isolators, surge protectors)
陈小姐 个人微信二维码

Scan WeChat QR code to add personal WeChat

QQ:2501529964

Phone:17717626508

Email:chenjing@qishan-sh.com

Miss Lu(Field Instruments, Valve Accessories, Terminal Blocks)
卢小姐 个人微信二维码

Scan WeChat QR code to add personal WeChat

QQ:1695457483

Phone:13636420802

Email:lhm@qishan-sh.com

Mr. Ye(Technical Support, After-Sales Service)

QQ:97010638

Phone:15800474322

Email:web@qishan-sh.com

Online Message

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Please enter the requirement description (at least 10 characters)