HiDMux2700 Type 32-channel HART multiplexer
32 channels, 24 V DC supply, HART field device inputs (protocol versions 5–7), RS-485 interface.
- Original Factory Genuine, Tenfold Compensation for Counterfeits
- Full Machine Warranty, Lifetime Maintenance
- In Stock, Shipped on the Same Day
Pepperl+Fuchs HiDMux2700 HART multiplexer, 32 channels, 24 V DC supply, HART field device inputs (protocol versions 5–7), RS-485 interface, up to SIL 3 (in accordance with IEC/EN 61508).
Part of the HART Interface Devices series, used for communication access, signal tapping and commissioning configuration between DCS/PLC control systems and HART field instruments, supporting HART protocol (including WirelessHART) multiplexing, loop conversion and filtering, and compatible with mainstream barriers and termination boards.
| Parameter Name | Technical Specifications |
|---|---|
| Functional safety parameters | |
| Safety Integrity Level (SIL) | SIL 3 |
| Power Supply | |
| Connection | SL1: 1a, 1b(-); 2a, 2b(+) |
| Rated Voltage | 20.4 … 30 V DC via termination board |
| Rated current | 28 mA at 24 V, RS-485, quiescent current |
| Power dissipation | 0.7 W at 24 V |
| HART signal channel (non-intrinsically safe) | |
| Number of Channels | 32 |
| Conformity | HART field device input (protocol version 5–7) |
| Signal range | 0.12 Vpp < signal < 1.5 Vpp |
| Leakage current | < 3 µA at −20 … 85 °C (−4 … 185 °F) |
| Terminating resistor | external 230 … 500 Ω standard (up to 1000 Ω possible) |
| Output voltage | ≥ 400 mV ss (with the above terminating resistor) |
| Output resistance | ≤100 Ω, capacitively coupled |
| DC isolation | Dual capacitor per channel |
| Common-mode voltage | up to 30 V |
| Input Impedance | > 5 kΩ, according to HART specification |
| Input voltage range | 0.12 … 1.5 V ss |
| Common-mode voltage | Max. 30 V |
| Differential-mode clamping | ± 5.2 V (transient or AC signal) |
| Common-mode clamping | ± 10 V (transient or AC signal) |
| Carrier detection level | signal > 0.12 Vpp, carrier detection activated, signal < 0.08 Vpp, carrier detection not activated |
| Transmit amplitude | 200 Ω load, 0.43 Vpp < signal < 0.49 Vpp, 500 Ω load, 1.1 Vpp < signal < 1.2 Vpp |
| Device type | DC isolated bus device |
| Impedance | High impedance |
| Data link type | HART primary and secondary |
| Field-side multidrop support | Optional, consult factory |
| Interface | |
| Transmission Rate | 9600/19200/38400 MBit/s, selectable via switch |
| Address | 1 … 31 (adjustable via DIP switch) |
| Type | RS-485, differential pair and grounding |
| Topology | Multidrop, master module/slave module connection |
| Electrical Isolation | |
| Interface/power supply | 500 Vrms |
| Interface/field channel | 1000 Veff |
| Power supply/field channel | 1000 Veff |
| Indication/setting | |
| Display elements | LEDs, LED PWR ON (power supply), one green LED, LED HART TX (HART transmission), one yellow LED, LED FAULT (lead fault), one red LED |
| Operating elements | DIP switch on the side of the housing, for: slave module address, baud rate, test mode on/off |
| Configuration | via DIP switch |
| Marking | Reserved marking area on the front |
| Directive conformity | |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
| Conformity | |
| Electromagnetic compatibility | NE 21:2012, see system description |
| Degree of protection | IEC 60529:2001 |
| Ambient Conditions | |
| Ambient Temperature | −20 … 60 °C (−4 … 140 °F) |
| Relative Humidity | 5 … 95 %, non-condensing |
| Mechanical parameters | |
| Degree of protection | IP20 |
| Weight | approx. 140 g |
| Dimensions | 18 x 114 x 130 mm (0.7 x 4.5 x 5.1 inch) (W × H × D) |
| Installation Method | Located on the termination board |
| Hazardous area application data | |
| Certificate | CML 17 ATEX 3337X |
| Marking | II 3G Ex ec IIC T4 Gc |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020, EN 60079-7:2015+A1:2018 |
| International approvals | |
| CSA certificate | 1256050 |
| Certification scope | Class I, Division 2, Groups A, B, C, D and non-explosion hazardous area |
| IECEx certificate | IECEx CML 17.0178X |
| IECEx marking | Ex ec IIC T4 Gc |
| General information | |
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals and manuals within the applicable scope. For related information, see www.pepperl-fuchs.com. |
- 32 channels
- 24 V DC supply
- HART field device input (protocol version 5–7)
- RS-485 interface
- Up to SIL 3 (in accordance with IEC/EN 61508)
Petrochemical Plant
HART field instrument commissioning and configuration communication
Power Energy System
DCS system HART multiplexer access
Process Automation
HART signal filtering and tapping between control room and field instruments
Documents not uploaded. Please fill in the information row by row in the 'Product Details Field' panel under 'File Name | Download Address | File Size'.
Need selection advice or bulk quotation?
Send us the working condition parameters (signal type, medium, range, pressure, temperature, connection method), and our engineers will provide a selection scheme and quotation within 1 working day.
- Phone consultation +86-21-66020232
- Email inquiry web@qishan-sh.com