Intrinsically safe types may also be used in combustible dust environments, based on GB/T 3836.31 (equivalent to the dust part of the IEC 60079-31 system) and the historical requirements of the GB 12476 series. The marking format differs from that for gas atmospheres:Ex ia IIIC T135°C Da.
Three Differences from Gas Atmospheres
- Group changed to IIIC: Dust is classified by conductivity into IIIA (combustible flyings), IIIB (non-conductive dust) and IIIC (conductive dust). IIIC is the most stringent; metal dust falls into this category;
- Temperature given as a value rather than a T class: The ignition characteristics of dust layers differ from those of gas clouds, so the maximum surface temperature is usually given directly (e.g. T135°C), and a distinction must be made between the "with dust layer" and "without dust layer" conditions;
- Dust layer thickness matters: Dust accumulating on equipment surfaces forms an insulating layer; a 5 mm dust layer can raise the surface temperature significantly, so values must be selected according to the actual dust accumulation conditions.
| Dust category | Example | Marking | Note |
|---|---|---|---|
| IIIA | Paper scraps, cotton fibres | Ex ia IIIA | Lint easily accumulates in ventilation holes |
| IIIB | Flour, sugar powder, plastic powder | Ex ia IIIB | Non-conductive, but equally explosive |
| IIIC | Aluminium powder, magnesium powder, iron powder | Ex ia IIIC | Conductive dust can bridge circuits — the most stringent |
Easily overlooked points:Intrinsically safe circuits in dusty locations must consider, in addition to electrical energy limitation,dust ingress into the enclosurecausing creepage and short circuits. Therefore the IP rating is usually required to be no less than IP6X, and terminals should have a dust-proof construction. Electrical energy limitation alone, without addressing the degree of protection, does not constitute actual safety.