The string of characters on the nameplate is the device's "identity document", specifying from left to right the type of protection, applicable gas, temperature class and level of protection.

| Position | Meaning | Value in this example | Other common values |
|---|---|---|---|
| Ex | Explosion protection equipment marking | Ex | — |
| Type of protection | Explosion protection technique and level | ia (intrinsic safety, two faults) | d flameproof, e increased safety, p pressurization, m encapsulation, ib, ic |
| Gas group | Applicable gas category | IIC | I (coal mining), IIA, IIB, IIIC (dust) |
| Temperature class | Maximum surface temperature | T4 (135 °C) | T1 to T6; for dust, T followed by the temperature value |
| EPL | Equipment protection level | Ga | Gb, Gc, Da, Db, Dc, Ma, Mb |
Verification points:The nameplate marking must match the explosion protection certificate. Cases are occasionally seen on site where the nameplate states ia but the certificate states ib (usually refurbished or re-marked units); such equipment should be taken out of service and its source traced. Also note the "Ta" or ambient temperature range marking on the label; operation outside that range is likewise non-compliant.