GB/T 3836.4 (identical to IEC 60079-11) is the technical core of intrinsic safety explosion protection. Its requirements can be summarised in four aspects.
1. Energy limitation
- Determine the permitted values according to the spark ignition curves:
Uo / Io / Po, and link them to the gas group; - Category ia must consider two independent faults, ib considers one fault, ic disregards faults;
- Voltage-limiting components (Zener diodes) must meet power and redundancy requirements, and current-limiting resistors must be non-flammable.
2. Energy storage limitation
Specify the calculation method for Co / Lo and require consideration of cable distributed parameters. For circuits with large capacitance or inductance, a dedicated energy storage assessment is required.
3. Construction and isolation
- Sufficient creepage distance and clearance must exist between intrinsically safe circuits and non-intrinsically safe circuits;
- Intrinsically safe circuit terminals must be arranged separately from other terminals and clearly marked (e.g. blue);
- Isolated equipment must meet the specified isolation withstand voltage.
4. Marking and documentation
Equipment must be marked with the Ex marking, parameter table (Uo/Io/Po/Co/Lo or Ui/Ii/Pi/Ci/Li) , ambient temperature range, and certificate number. The instruction manual must state installation and usage limitations.
Direct implications for users:The parameter table requested during selection is precisely what this standard requires manufacturers to provide. If a supplier cannot produce complete
Uo/Io/Po/Co/Lodata, it indicates that their product documentation does not comply with the standard, and subsequent system calculations cannot be performed — this in itself is a hard criterion for screening suppliers.