IP ratings are classified according to GB/T 4208 / IEC 60529; the first digit indicates protection against solid foreign objects, the second against water. Intrinsically safe equipment commonly requires a minimum of IP54, with IP65/IP66 needed for outdoor or washdown applications.
| IP rating | Protection capability | Typical installation location |
|---|---|---|
| IP54 | Dust-protected (limited ingress), splash-proof | Indoor control cabinets, analyser shelters |
| IP65 | Dust-tight, water jet protected | Outdoor open-air installation, chemical plant areas |
| IP66 | Dust-tight, protected against powerful water jets | Washdown areas, coastal high-humidity environments |
| IP67 | Dust-tight, protected against short-term immersion | Pits prone to water accumulation, low points in tank farms |
Two concepts must be distinguished:The IP rating governs enclosure protection; the Ex rating governs ignition risk. The two cannot substitute for each other. An ordinary IP68 device installed in Zone 1 is still non-compliant; an Ex ia device rated only IP20 installed outdoors will also fail due to water ingress.
Cable entries are the weak point:Many field devices achieve IP66 on the body, but if ordinary cable glands are used at the cable entry, the actual protection level drops below IP44. During selection, cable sealing glands and blanking plugs should be specified to the same rating, and at acceptance checks confirm they are tightened and the sealing rings are correctly seated.